Indoor Unit - Panasonic CS-S9TKV Service Manual

Hide thumbs Also See for CS-S9TKV:
Table of Contents

Advertisement

10.2 Indoor Unit

10.2.1
How to Fix Installation Plate
The mounting wall shall be strong and solid enough to prevent it from the vibration.
Measuring
Tape
S9***, S12***
Measuring
Tape
S18***, S24***
The center of installation plate should be at more than 1 at right and left of the wall.
The distance from installation plate edge to ceiling should more than 2.
From installation plate center to unit's left side is 3.
From installation plate center to unit's right side is 4.
B
: For left side piping, piping connection for liquid should be about 5 from this line.
: For left side piping, piping connection for gas should be about 6 from this line.
1. Mount the installation plate on the wall with 5 screws or more (at least 5 screws).
(If mounting the unit on the concrete wall, consider using anchor bolts.)
Always mount the installation plate horizontally by aligning the marking-off line with the thread and using
o
a level gauge.
2. Drill the piping plate hole with ø70 mm hole-core drill.
Putting measuring tape at position as shown in the diagram above.
o
The hole center is obtained by measuring the distance namely 128 mm for left and right hole
respectively. Another method is intersection point of arrow mark extension.
The meeting point of the extension arrow mark is the hole center position.
Drill the piping hole at either the right or the left and the hole should be slightly slanting to the outdoor
o
side. (refer to 10.2.2)
Wall
More than 1
266 mm
PIPE
HOLE
CENTER
128mmTO
PIPE HOLE
CENTER
128 mm
Model
Wall
More than 1
266 mm
128 mm
Model
Ceiling
More
2
screw
than 2
3
Installation plate
B
For best strength of
C
INDOOR unit installation,
it is highly recommended
to locate " " at 5 position
as shown.
1
2
515 mm
85 mm
Ceiling
More
2
screw
than 2
128 mm
Installation plate
For best strength of
INDOOR unit installation,
it is highly recommended
to locate " " at 5 position
as shown.
1
2
615 mm
95 mm
51
More than 1
Indoor unit
4
1
266 mm
PIPE
HOLE
CENTER
A
128mmTO
PIPE HOLE
CENTER
128 mm
Dimension
3
4
5
460 mm
460 mm
43 mm
More than 1
1
266 mm
128 mm
Dimension
3
4
5
560 mm
560 mm
270 mm
Wall
6
95 mm
Wall
6
320 mm

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents