Inserting/Replacing Activated Charcoal Filters; Changing The Lighting - privileg SY-3503C-P1-C81-L22-600 User Manual

Flue exhaust hood
Hide thumbs Also See for SY-3503C-P1-C81-L22-600:
Table of Contents

Advertisement

Available languages

Available languages

Page EN-18
Care and maintenance
Inserting/replacing activated
charcoal filters
Activated charcoal filters are required for
circulation air operation. They help combat
odours. They have to be replaced as soon as
the cooking odours can no longer be adequa-
tely filtered.
If used frequently, you should change the fil-
ters regularly. Check them at least every 6
months.
For the source of supply, please see chapter
"Our Service Centre" on page EN-20.
1. Unplug the mains plug or switch off the
corresponding circuit.
(9)
2. Push back the lock (9) on the grease fil-
ters (10) and carefully remove the grease
filters.
(11)
3. Only when replacing:
Unscrew the old activated coal filter (11)
from the motor and remove the activated
charcoal filter.
4. Put on the new charcoal filters to the right
and left of the motor and tighten them.
5. Re-insert the grease filters. To do this,
push the lock of the grease filters back,
press the grease filters upwards and re-
lease the lock. The grease filters will snap
into place.
6. Switch the power back on.
7. Dispose of the used charcoal filters with
household waste.

Changing the lighting

WARNING
Risk of injury!
Touching live parts may result in severe
injury or death.
■ If one of the LEDs ceases to work, it
must be changed by an authorised
service technician.
Note for the service technician:
This exhaust hood requires LEDs with the
(10)
ILCOS D-Code DBR-2/65-H-64, 110–240 V~,
2 W.