6.5.4 Connecting the Communication Cable (optional)

communication cable far away from any interference source or power cable to prevent the
• Connect the RS485 cable, remote shutdown cable, meter cable, and CT cable using a 2PIN
communication terminal.
• Connect the dry contact cable and DRED cable using a 6PIN communication terminal.
• Remove the short circuit wire and keep it properly when enabling the DRED function.
Turn on S0 and the inverter shuts
down.
to on-grid.
Turn on S5 and the inverter does
Turn on S6 and the inverter outputs
its rated power.
Turn on S7 and the inverter outputs
its rated power. In the meantime,
the inverter consumes the
maximum Reactive Power.
Turn on S8 and the inverter is back
Notice
Note
-
When two or more than
simultaneously, select any
two of them can satisfy the
strictest requirement.
27
Electrical Connection