Operating Procedure For Auto Regeneration Mode; Regeneration Operating Procedure For Auto Regeneration Mode - Kubota MX Series Operator's Manual

Table of Contents

Advertisement

 OPERATING THE ENGINE

3.1 Operating procedure for Auto Regeneration mode

3.1.1 Regeneration operating procedure for Auto Regeneration mode

(1) DPF INHIBIT switch
(2) Parked regeneration switch
1. Start the engine.
Make sure that the DPF-INHIBIT-switch-lamp
DPF INHIBIT switch lamp is off
"Auto Regeneration" mode is activated.
DPF INHIBIT switch lamp is on
"Regeneration Inhibit" mode is activated.
NOTE :
• When the engine is started, the "Auto Regeneration" mode is automatically activated.
• "Regeneration Inhibit" mode is activated when the DPF-INHIBIT-switch is pushed after the engine is
started.
2. When the regeneration indicator
Continue to operate the tractor. The regeneration process will begin automatically. Make sure that the working
place is in a safe area because DPF and exhaust temperature will rise.
3. When the engine-rpm-increase-indicator
the engine-rpm-increase-indicator turns "OFF".
NOTE :
• Even if the "Auto Regeneration" mod is selected, DPF regeneration may not begin because system
requirements have not been satisfied.
• The engine-rpm-increase-indicator is used as a guide to satisfy the regeneration conditions. If the engine
load is too heavy, the engine-rpm-increase-indicator may continue to flash, even though regeneration
system conditions are satisfied and regeneration may begin automatically.
(See Tips on diesel particulate filter (DPF) regeneration on page 57)
52
(3) Regeneration indicator
(4) Parked regeneration indicator
is "OFF".
starts flashing, a specific amount of PM has built up in the DPF.
starts flashing, keep on working and increase the engine rpm until
EXHAUST AFTERTREATMENT DEVICES
(5) Engine rpm increase indicator
(6) Engine warning indicator
MX5400,MX6000

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx5400Mx6000

Table of Contents