6.1
Replace bearing plate
Figure 6-2 Loosen screw
Figure 6-3 Remove bearing plate
35 – www.uniflex.de
UNIFLEX-Hydraulik -
To replace the bearing plates:
Loosen the screws fixing the bearing
plates on the compression place using a 3
mm Allen wrench..
Slide the bearing plates up to remove
them.Insert new bearing plates.
Tighten all of the screws fixing the bearing
plates finger tight.Check the zero point
setting in a test crimping process.
Maintenance