Installation
This section describes the installation and setup of the NetPA U 8001 SUB power amplifier. Topics
include:
•
•
Mounting the NetPA U 8001 SUB
The NetPA U 8001 SUB amplifier can be:
•
•
•
Tabletop Use
Four self-adhesive rubber feet are included. Attach one foot at each corner on the bottom
side of the amplifier and place the unit in a desired location.
Rack Mounting
The NetPA U 8001 SUB amplifier can be mounted in a rack using one of the following
methods:
•
•
•
Rack Mounting Ventilation Recommendations
Excessive heat decreases the optimal
lifetime of the power amplifier. An Over
Temp indicator LED on the front panel of
the amplifier lights red whenever the
recommended operating temperature has
been exceeded.
In a rack environment, the amplifier can
be arranged above or below another non-
NetPA Ultra device, but the environment
around the unit must not reach or go
beyond +122°F (+50°C). To minimize heat,
stack no more than four devices, one-on-
top-of-the-other, without an open space in
between (see figure 1).
Mounting the NetPA U 8001 SUB
Flexible Conduit Adapter Kit Installation
Set on a table
Mounted in a rack
Mounted to the SF 10C SUB in-ceiling subwoofer in the plenum space
Rack ear mounting (see
page
Bridge plate mounting (mounts two amplifiers, see
page
Rack shelf mounting (see
5)
page
6)
7)