M4 x 20 DIN7984
TERMINAL
SCREW
BADGE

FITTINGS AND TUBING

TUBING
M3 x 10 AX1 SCREW
STEP 3
EK- PLUG G1/4
EK-FITTING
STEP 3
Place seven (7) M3 x 10 AX1 screws into the water block standoffs
and tighten them using a Philips head screwdriver (as shown in the
image). After attaching the AX1 Screws, three (3) terminal screws
M4 x 20 DIN7984 need to be attached using Allen Key 2.5 mm. The
terminal badge can be reused, after securing the terminal screws.
For this step, you will need:
Phillips Head Screwdriver
Screw in two (2) G1/4 threaded male fittings. Attach the liquid
cooling tubes and connect the water block to the cooling loop.
Do not forget to plug the remaining two openings with the
enclosed EK-Plug G1/4 or its equivalent.
EK recommends using EK fittings with all EK water blocks.
CAUTION: When using connectors other than EK fittings,
pay special attention to the length of the fittings' male G1/4"
thread – 5 mm is the maximum G1/4" thread length allowed!
- 15 -
Allen Key 2.5mm