Download Print this page

Allen-Bradley 700-HX User Manual page 8

Multifunction digital timer

Advertisement

2-2
Product Features
Engineering Data
(Reference Values)
1,000
500
100
30V DC L /R=7 ms
50
10
250V A C cos =0.4
0
1
2
3
Specifications
Electrical Ratings
Pilot Duty Rating
Rated supply voltage
Operating voltage range
Power consumption
Inrush Current
120V AC
Make
240V AC
120V AC
Break
240V AC
Hp at 120V AC
Hp at 240V AC
Mechanical
Mounting method
Display
Digits
Timer
Publication 700-UM002A-EN-D - July 2001
250V DC/30V
cos =1
4
5
Load current (A)
100...240V AC
24V AC/12...24V DC
100...240V AC
24V AC/12...24V DC
Time ranges
Timer modes
Output modes
Reference:A maximum current of 0.15 A can be switched
at 125V DC (cosφ=1) and a maximum current of 0.1 A
can be switched if L/R is 7 ms. In both cases, a life of
100,000 operations can be expected. The minimum
applicable load is 10 mA at 5V DC (failure level: P).
NEMA B300
100 to 240V AC, 24V AC/12 to 24V DC (50/60Hz) (permissible
ripple: 20%(p-p) max.)
85%...110% of rated supply voltage
4.3 VA
3.4 VA/1.7 W
3 A
5 A
30 A
15 A
3 A
1.5 A
1/4 Hp
1/3 Hp
Flush mounting, surface mounting, DIN mounting
7-segment, negative transmissive LCD;
Present value (red, 8 mm high characters); Set value (green,
4 mm high characters)
4 digits
0.000...9.999 s, 0.00...99.99 s, 0.0...999.9 s, 0...9999 s,
0 min. 0.0 s...99 min. 59 s, 0.0...999.9 min., 0 h 00 min....99
h 59 min., 0.0 h...999.9 h, 0 h...9999 h
Elapsed time (Up), remaining time (Down), selectable
A, A-1, A-2, A-3, B, B-1, D, E, F, Z, ton or toff

Advertisement

loading

This manual is also suitable for:

700-hx86sa17700-hx86su24