Operation (Twin Timer
Function)
Present Value and Cycle Time (Output Mode = Z)
The present value is displayed in the main display and the cycle time is
displayed in the sub-display. "SET2" lights at the same time.
Set the cycle time used in ON/OFF-duty adjustable Repeat Cycle (Z).
Cycle time
ON duty (%)
Output control
Switching from Timer to Twin Timer
The 700-HX is factory-set for timer operation. To switch to twin timer
operation, use the procedure given below. For details, refer to page 3-1.
Timer/twin timer selection mode
Function
selection
Switch from timer operation to twin timer
operation using the
Elapsed cycle time
ON duty set as a percentage
Up/down keys used for analog
adjustment of the ON duty
Close
Opening/closing valve
Fully closed↔Fully open
ON duty
0%↔100%
Power ON
Run mode
Hold down for
1
1 s min.
keys.
Publication 700-UM002A-EN-D - July 2001
Functions
3-5
Open