Infineon XENSIV BGT60LTR11AIP Manual page 19

Hide thumbs Also See for XENSIV BGT60LTR11AIP:
Table of Contents

Advertisement

XENSIV™ BGT60LTR11AIP Radar Shield2Go
Super low-power 60 GHz Doppler radar sensor with antennas-in-package
Radar modes setup
QS3 is used to select the hold time of the T
BGT60LTR11AIP User
Guide.
QS3 settings – detector hold time
Pad
0*V
/16 – 1*V
/16
DD
DD
1*V
/16 – 2*V
/16
DD
DD
2*V
/16 – 3*V
/16
DD
DD
3*V
/16 – 4*V
/16
DD
DD
4*V
/16 – 5*V
/16
DD
DD
5*V
/16 – 6*V
/16
DD
DD
6*V
/16 – 7*V
/16
DD
DD
7*V
/16 – 8*V
/16
DD
DD
8*V
/16 – 9*V
/16
DD
DD
9*V
/16 – 10*V
/16
DD
DD
10*V
/16 – 11*V
/16
DD
DD
11*V
/16 – 12*V
/16
DD
DD
12*V
/16 – 13*V
/16
DD
DD
13*V
/16 – 14*V
/16
DD
DD
14*V
/16 – 15*V
/16
DD
DD
15*V
/16 – 16*VDD/16
DD
Due to mechanical tolerances and manufacturing differences in the potentiometer, it is difficult to predict the
degree of rotation of the potentiometer. Table 7 gives an orientation for the configuration of the QS3 voltage,
hence the radar's hold-time. Please note that your values may differ slightly from the values below.
Measured voltage vs. hold-time of QS3 potentiometer in autonomous mode (for reference
only)
Measured
potentiometer voltage
QS3
0 V
0.112 V
0.279 V
0.355 V
0.493 V
0.713 V
0.898 V
1.06 V
1.134 V
1.248 V
1.452 V
Application Note
output, and it is written into Reg10 as described in the
det_o
Detector hold time
100 ms (left endpoint of potentiometer)
500 ms
1 s
2 s
3 s
5 s
10 s
30 s
45 s
1 min.
90 s
2 min.
5 min.
10 min.
15 min.
30 min. (right endpoint of potentiometer)
Expected detector hold-
time
100 ms
500 ms
1 s
2 s
5 s
30 s
60s
90 s
2 min.
5 min.
15 min.
page 19 of 32
Measured detector hold-
time
Less than 1 s
Less than 1 s
1.37 s
2.21s
5.54 s
30 s
60s
90 s
2 min.
5 min.
15 min.
Comment
Leftmost position
Rightmost position
V1.0
2022-12-15

Advertisement

Table of Contents
loading

Table of Contents