9 Disassembly Guide

Pictures are provided as a reference only. Each unit will be different
depending on the your model number.

9.1 Outdoor Unit - BMS500-AAM018-1CSXRC

9.1.1 Removing the panel plates
1. Stop operation of the system and turn "OFF" the power at the disconnect.
2. Remove the big handle (3 screws).
Screws of
big handle
Figure 92
3. Remove the top cover (3 screws).
Figure 93
Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Multi Zone Outdoor Units (01.2023)
4. Remove the front panel (7 screws).
Figure 94
Screws
Figure 95
5. Remove the screws of water collector, and remove the water collector. (3
Figure 96
Screws of front panel
Screws of front panel
Screws of front panel
screws)
Screws of water collector
Service Manual