Other Functions; Setting The Swing Function; Setting The Air Guide Function; Changing Over Display And Alarm Buzzer - Bosch Climate 5000L Operating Instructions For Users

Large split air conditioner
Table of Contents

Advertisement

You can not program the on timer and off timer to operate the unit at
different temperatures or with other settings.
3.8

Other functions

3.8.1

Setting the swing function

NOTICE
If the louvre remains at the lowest position during cooling mode for an
extended period, condensate may be discharged. Adjusting the louvre
by hand may cause faults.
▶ Only use the remote control to adjust the louvre.
Automatic vertical Swing mode (up/down)
▶ Press the Swing key until the symbol
▶ To cancel the automatic vertical Swing mode: press the Swing key
again.
Cleaning position
To make cleaning easier, the louvre can be brought into a special position
(depending on product type).
▶ Press the Mode and Swing keys simultaneously for one second when
the device is switched off.
▶ To exit the cleaning position: press and hold both keys again.
3.8.2
Setting the air guide function (only CL5000iL 4C ...)
▶ Press the Vane key until the desired louvre is selected.
The setting changes in the following sequence:
-1
-2
-3
-4
-0 indicates that all 4 louvres have been selected.
3.8.3
Changing over display and alarm buzzer (Mute Mode)
▶ To switch on or off the display at the indoor unit and the alarm buzzer:
press LED key.
▶ To display the current room temperature, press the LED key and hold
for 5 seconds.
▶ To display the set temperature: press and hold the LED key for
another 5 seconds.
3.8.4

Energy saving functions

Energy saving functions can only be selected in cooling mode.
The following energy saving functions can be selected at the device:
• ECO: operation with fan speed AUTO and set temperature of at least
24 °C
• GEAR (75%): reduce power consumption by 25%
• GEAR (50%): reduce power consumption by 50%
• None of the above symbols: normal operation
▶ To activate an energy saving function, press
required function is displayed.
The ECO function automatically sets a temperature of 24 °C if the
previously set temperature is lower. The function switches off as soon as
the temperature is lowered to less than 24 °C.
Climate 5000i U/L – 6721841495 (2021/10)
appears.
-0
key until the
3.8.5

Noise reduction (Silent Mode)

This function reduces the noises emitted by the indoor and outdoor unit
when it is in operation. This is particularly advantageous at night, if you
need to show consideration for your neighbours.
▶ During operation, press the
Exiting the function:
▶ Press the
key again for 2 seconds.
-or-
▶ Press the K key, Mode key, Turbo key or Clean key.
When the outdoor unit is in quiet mode, it may not be possible to achieve
the required cooling/heating capacity because the compressor operates
at a low frequency.
3.8.6

Turbo cool/Turbo heat

When Turbo cool/Turbo heat is active, the indoor unit operates at
maximum power to heat or cool the room quickly.
▶ Turbo cool: switch on Cooling mode and press the Turbo key.
▶ Turbo heat: switch on heating mode and press the Turbo key.
Exiting the function:
▶ Press the Turbo key again.
3.8.7
Self-cleaning CL5000iU 4CC ... (I clean)
The device has a self-cleaning function for the evaporator. The self-
cleaning freezes the evaporator. Everything is then quickly defrosted and
dried with hot air. As a result, dust, mould and grease are removed
through the condensate pipe.
▶ To activate the self-cleaning: press the Clean key.
CL appears on the display of the indoor unit when self-cleaning is in
progress. Self-cleaning ends automatically after 20 to 45 minutes.
Self-cleaning product type CL5000iL 4C ...: see chapter
 Self-cleaning (, CL5000iL 4C ...), page 38.
3.8.8

Indirect airflow (Wind avoid me)

▶ To activate the indirect airflow: press
This function prevents a direct airflow on to persons.
The function is only available in cooling mode, dehumidification mode
and Fan Mode.
3.8.9

Key lock function

CL5000iU 4CC ...
The keys of the remote control can be locked with the keylock.
▶ To switch the keylock on/off: press the Clean and Turbo keys
simultaneously for 5 seconds.
The symbol
appears in the display when the keylock is active.
CL5000iL 4C ...
The keys of the remote control can be locked with the keylock.
▶ To switch the keylock on/off: press the Vane and Turbo keys
simultaneously for 5 seconds.
The symbol
appears in the display when the keylock is active.
Operation
key for 2 seconds.
key.