Bosch Climate 5000 Series Service Manual page 95

Ductless air conditioner / heat pump multi zone outdoor units
Hide thumbs Also See for Climate 5000 Series:
Table of Contents

Advertisement

9.2.4 Removing the compressor
1. Follow steps outlined in Sections 9.2.1, 9.2.2 & 9.2.3.
2. Recover refrigerant from the refrigerant circuit.
3. Remove the sound insulation material and crankcase heating cable.
4. Remove terminal cover of compressor and disconnect wires of compressor
thermo and compressor from the terminal.
5. Apply heat and remove discharge and suction pipes.
Figure 128
6. Remove the hex nuts and washers fixing the compressor on bottom plate.
Figure 129
7. Lift the compressor from the base pan assembly.
Bosch Climate 5000 Series Ductless Air Conditioner / Heat Pump Multi Zone Outdoor Units (01.2023)
9.2.5 Removing the reactor
1. Follow steps outlined in Sections 9.2.1 & 9.2.2.
2. Disconnect the connection between the reactor and IPM board.
3. Remove the cover of inductance (2 screws).
Figure 130
4. Disconnect two pieces of wires connected from the cover of inductance.
5. Remove the reactor (4 screws).
Figure 131
Service Manual
Inductance
Cover
Screws
Screws of
reactor
| 95

Hide quick links:

Advertisement

Table of Contents
loading