Troubleshooting And Fault Rectification For Lubricator - CompAir L15 Operating And Service Manual

Screw air compressor
Hide thumbs Also See for L15:
Table of Contents

Advertisement

9. Service and maintenance
9.2.7

Troubleshooting and fault rectification for lubricator

If faults occur when operating the lubricator, please check the possible causes of error using the following table. If an
error occurs that isnʼt listed in the table, please contact CompAir customer service.
Error function and error
messages
GREEN
RED
Description of error
Lubrication system is not
functioning despite the
voltage being applied.
Lubrication system is not
functioning despite the
voltage being applied. Plug
icon is visible on the
display.
Lubrication system is in
pressure cut-off.
RED
Lubricant cartridge empty,
but an "LC" message is not
displayed.
"LC" message although
lubricant cartridge is not
completely empty.
Cause of error
- Cable breakage
- Incorrect wiring
Drive and LC not screwed
down correctly.
Back pressure on
lubrication point > 6 bar.
LC unit too small for the
drive.
LC unit too big for the
drive.
Error rectification
Check whether the plug icon
is shown on the display
Screw the drive and LC
together until the white
triangle can be fully seen on
the drive.
- Rinse lubrication point
(manually or special
PURGE l).
- If required, check
pressure.
- Acknowledge error by
confirming with the SET
button.
Use original LC unit
MLS 120 from CompAir
Use original LC unit
MLS 120 from CompAir
41