Annex; Technical Data; Europe Version L90-L110 50 Hz A - Air-Cooled W - Water-Cooled - CompAir L15 Operating And Service Manual

Screw air compressor
Hide thumbs Also See for L15:
Table of Contents

Advertisement

11. Annex

11
Ann ex

11.1 Technical Data

11.1.1 EUROPE version L90-L110 50 Hz
Technical data 50Hz
Maximum operating pressure
Minimum operating pressure
Ambient temperature
Flow
After-cooler outlet temperature
above ambient temp.
Sound pressure level (to ISO 2151)
Nominal motor rating
Full-load current max. IP55
(220V, 380V, 400V)
Motor protection type
Nominal speed
Nominal fan motor power
Recommended cable cross-section
at 75 °C (220V / 380V / 400V)
Recommended fuse size
(220V / 380V / 400V), slow-blowing
Cooling air flow through ventilator
Cooling air outlet temperature above
ambient temp.
Max. allowable pressure drop in duct at
ambient 35°C / 45°C
Cooling water quantity
Cooling water inlet temperature
Cooling water outlet temperature
Cooling water pressure
Cooling water connection
Compressed air delivery connections
(male screwed thread)
Weight
Dimensions L x W x H
A - air-cooled W - water-cooled
L90
7.5
10
bar
7.5
10
bar
°C
3
m
/min
17.45
15.47
A -°C
7
W - C
9
dB(A)
73
kW
90
A
360 / 204 / 190
-
rpm
kW
2
mm
2x3x95 PE50 / 3x95 PE50 / 3x70 PE35
A
250 AgL / 250 AgL / 200 AgL
3
m
/min
A - 223 / W - 100
°C
27
Pa
110 / 80
l/min
90 @∆T = 17K @∆p = 0.8 bar
°C
°C
bar (g)
-
kg
A - 2513 / W - 2377
mm
13
7.5
13
7.5
5
1...45
13.45
20.77
7
6
8
7
IP55 (IE2) , IEC 60034-2-1, ECA Qualifying
3000
A - 2.5 / W - 0.37(IP-54)
2x3x150 PE70 / 3x95 PE50/ 3x95 PE50
125 @∆T = 14K @∆p = 1.4 bar
min. 5 / max. 35
55
10
EN10226-1 Rp 1 1/4 (DIN 2999-R 1 1/4)
EN 10226 R 2 1/2" (DIN 2999-R 2 1/2)
2337 x 1368 x 2039
L110
10
10
18.63
16.21
8
8
9
8
75
110
437 / 244 / 228
315 AgL / 250 AgL / 250 AgL
A - 227 / W - 100
32
80 / 40
A - 2614 / W -- 2478
13
13
7
7
57

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents