7. Commissioning
7.5

Commissioning after malfunction

Important
Do not switch the screw compressor on repeatedly
without having rectified the malfunction, since this
may cause considerable damage to the machine.
Re-start after an automatic shutdown due to a
malfunction as follows:
Faults are shown as text in the compressor control
DELCOS XL "fault memory" display menu.
Turn master switch off and secure it from being
switched on again.
Eliminate fault.
Turn master switch on.
Acknowledge the fault in the fault memory menu.
After the acknowledgement, the message [READY
TO START] appears on the display, unless another
fault is present.
Press START button [ I ] (- 2 - Fig. 16).
7.6

Shutoff

To switch off the compressor use the O key (-3- Fig. 16)
and not the EMERGENCY STOP button. After shutdown
the compressor has a run on time of 30-50 seconds (soft-
stop).
Note
The unit may only be shut down using the emergency
off button in real emergencies. When shutting down
normally, please use the O key.
7.7

Emergency stop

The EMERGENCY STOP button is situated next to the
DELCOS XL. It is used to immediately shut down the
unit. Only use the EMERGENCY STOP button (-7- Fig.
16) to shut down the unit in emergencies. When
shutting down normally, always use the [O] key.
37