9. Service and maintenance
b) Control-cabinet inlet filter (L90RS - L132RS only)
• Open the louvred grilles of the inlet filter (Fig. 27).
• Remove the filter pad.
• Insert the new filter pad into the louvred grille.
Ensure that the smooth side (-A- Fig. 28) of the
filter pad faces the air inlet side.
• Place the louvred grille back onto the filter
housing.
Changing times for the filter mat
The operating modes and the quality of the suctioned
air (e.g. dust content) has a strong influence on the filter
service life.
The filter should be checked on a weekly basis,
eventually daily basis, for dust build-up.
In these operational cases, shorter change intervals are
possible.
9.13 Clean dirt interceptor (only for
Lxx W – water-cooled units)
Fig. 29
1 Dirt interceptor
2 Cooling water solenoid valve
3 Manual regulating valve
Warning
Only perform checks and carry out work on
the screw compressor when the unit is out
of operation, depressurized, and secured
from being switched on again!
Lock water inflow and water outflow on the compressor.
Provide a suitable container in order to catch any
cooling agents draining from the system.
Carefully loosen the cover of the dirt interceptor. Catch
any cooling agent draining from the system.
Remove cover and pull filter insert from the housing.
Clean filter insert or replace with a new one.
Push filter insert into the dirt interceptor housing.
Screw cover into the housing. Ensure that the seal is
correctly positioned and that there is no dirt on the
sealing ring and the sealing areas.
Tighten cover with a suitable tool.
Check all connections for tightness.
Open water inflow and outflow at the compressor.