11. Annex
11.1.7 EUROPE version L132RS
Technical data 50 / 60Hz
Maximum operating pressure
Minimum operating pressure
Ambient temperature
7.5 bar
Flow
9 bar
Flow
10 bar
Flow
13 bar
Flow
After-cooler outlet temperature above ambient temp. (at full load)
Sound pressure level (to ISO 2151 at 70% load / at full load)
Nominal motor rating
Voltage (frequency)
Full-load current max. (380V / 400V / 460V)
Motor protection type
Nominal speed
Nominal fan motor power
Recommended cable cross-section at 75 °C (380V/400V/460V)
Recommended fuse size (380V/400V/460V), slow-blowing (type gG)
Cooling air flow through ventilator
Cooling air outlet temperature above ambient temp.
Max. allowable pressure drop in duct at ambient 35°C / 45°C
Cooling water quantity
Cooling water inlet temperature
Cooling water outlet temperature
Cooling water pressure
Cooling water connection
Total oil volume
Compressed air delivery connections (male screwed thread)
Weight
Dimensions L x W x H
A - air-cooled W - water-cooled
bar
bar
°C
3
m
3
m
3
m
3
m
°C
dB(A)
kW
rpm
A - kW
W - kW
mm
3
m
3
m
°C
Pa
l/min
°C
°C
bar (g)
kg
mm
at min. speed
/ min
4.76
/ min
4.72
/ min
4.69
/ min
5.73
A - 8 / W - 9
380V[+10%-5%];400V[+/-10%];460V[+/-10%]
(50, 60Hz)
A
297 / 283 / 246
-
IP55, EFF1
650...2980
5.5 (50Hz) (IP54) ; 6.3 (60Hz) (IP54)
0.37 (50Hz) (IP54) ; 0.66 (60Hz) (IP54)
2
3x150PE95 / 3x150PE95 / 3x150PE95
A
300 / 300 / 250
/ min
A - 273 (50Hz) ; 248 (60Hz)
/ min
W - 100 (50Hz / 60Hz)
29 (50Hz) ; 30 (60Hz)
130 / 90 (50Hz) ; 70 / 40 (60Hz)
170 @∆T = 12K @∆p = 2.1 bar
min. 5 / max. 35
EN10226-1 Rp 1 1/4 (DIN 2999-R 1 1/4)
l
-
EN 10226 R 2 1/2 (DIN 2999-R 2 1/2)
2337 x 1368 x 2039
L132RS
13.0
5.0
1...45
at max. speed
22.72
21.18
20.08
17.26
74 / 77
132
55
10
54
2786
63