Page 1
O P E R A T I N G I N S T R U C T I O N S MPS-M Position sensor...
Page 2
Original document This document is an original document of SICK AG. O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK Subject to change without notice...
Put the sensor into operation for the first time........8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
Page 4
12.1 Dimensional drawing................Glossary....................36 Annex....................37 14.1 Conformities and certificates..............O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK Subject to change without notice...
Indicates a situation presenting possible danger, which may lead to death or serious injuries if not prevented. 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
Page 6
✓ The tick denotes the results of an action. O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK Subject to change without notice...
All work must only ever be carried out by the stipulated persons. ■ 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
The MPS-M determines the position of an encoder magnet via a row of 2 sensor elements located in the sensor head. 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
0-10 V. When leaving the measuring range, 11 V or 10.5 V are output. O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK...
Page 11
2,500 ... -2,500 digits (IO-Link output) Piston position Sensor position output 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
No error display via LEDs During position measurement via IO-Link, only LED2 (PWR) flashes O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK...
"Technical data", page ■ Relative humidity: see "Technical data", page ■ 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
When tightening the screw, use a non-magnetic Allen key. PWR LED = Power LED O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK...
Group 2: Cables sensitive to interference, such as sensor cables, communi‐ ° cation signals, bus signals 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
Page 16
Prevent equipotential bonding currents via the cable shield with a suitable earthing method, see "Safety", page O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK Subject to change without notice...
DIN VDE 0298 (part 4) and/or DIN VDE 0891 (part 1) 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
265 Position noise limit for application range [mm]: O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK...
Page 19
50 mm. To do so, the desired start and end point must be entered in digits (1 digit = 10 µm) in the corresponding subindex. 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
3. Alternatively, alert notifications can be output via byte 3 instead of switching points. O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK...
2 (0x02) System Command, value 130). The measured values of the algorithm are also reset, see Reset trained algorithm parameter. 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
Page 22
Qint.1 Configuration. The index for configuring setpoint 2 directly follows the index for setpoint 1 Qint. 1. O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK...
Page 23
The hysteresis is symmetrical around each Qint.SP. 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
Page 24
Qint.SPx and Qint.SPy, the signal is high. As soon as the magnet is below Qint.SPx, the signal is low. (Qint.SPx < Qint.SPy) O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK...
Page 25
– 25 mm Switching range Direction of movement of the magnet 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
Page 26
NOTE This applies to the Cylinder switch mode switching point mode only. O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK Subject to change without notice...
The measured travel of the last stroke in mm is output via index 4372 (0x1114) Actuator travel [x10µm]. 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
Page 28
1 is in the direction of the cable of the sensor and sensor element 2 is in the direction of the fixing screw of the sensor. O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK...
Page 29
(subindex 2 (0x02) Since last reset)). 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
Both LEDs flash quickly Incorrect sensor configuration Perform a factory reset detected O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK Subject to change without notice...
Subject to change without notice. Specified product properties and technical data are not written guarantees. 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
Description of the application ■ Description of the fault that occurred ■ O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK Subject to change without notice...
D = Outputs overcurrent and short-circuit protected Installed in the drive groove. 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
Cable with M8 male connector Physical zero position Fixing screw, size 2.5 O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK Subject to change without notice...
Page 35
Physical zero position Fixing screw, size 2.5 Retaining ribs 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
The sampling rate indicates the time interval in which the signal is updated at the outputs. The sampling rate is min. 2 kHz. O P E R A T I N G I N S T R U C T I O N S | MPS-M 8028183/2022-12-30 | SICK...
(part number: see the entry in the “P/N” or “Ident. no.” field on the type label). 8028183/2022-12-30 | SICK O P E R A T I N G I N S T R U C T I O N S | MPS-M Subject to change without notice...
Page 38
Phone +65 6744 3732 Phone +30 210 6825100 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail office@sick.com.gr E-Mail sales.gsg@sick.com Hong Kong Slovakia Phone +852 2153 6300 Phone +421 482 901 201 E-Mail ghk@sick.com.hk E-Mail mail@sick-sk.sk Detailed addresses and further locations at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...