8 Technical Information

8.1 Operating environment

Temperature
From -20 to 50°C (-4-122°F), unless otherwise indicated on the data plates of the pump and
the electric motor.
Relative air humidity
< 50% at 40°C (104°F), unless otherwise indicated in the instructions of the pump and the
electric motor.
NOTE:
If the humidity exceeds the stated limits, contact Xylem or the Authorised Distributor.
Elevation
< 1000 m (3280 ft) above sea level.
NOTE: Danger of motor overheating
If the unit is exposed to temperatures or installed at an altitude greater than those stated, refer
to the motor manufacturer's instructions and catalogues to reduce the power output of the
motor or replace it with a more powerful model.
Altitude m (ft)
1000–1500 (3300–4900)
1500–2000 (4900–6600)

8.2 Temperature of pumped liquid

The table shows the permitted liquid temperatures according to the material of the standard
non balanced seal with elastomeric bellow.
Seal material
BQ7EGG
BQ7VGG
Q7Q7EGG
Q7Q7VGG
Note: For the temperatures of the optional seals see the data plate.

8.3 Maximum operating pressure

The chart shows the pumped liquid pressure and temperature limits permitted for the
materials of the unit, depending on the type of flange.
e-IXPS - Installation, Operation and Maintenance Instructions
Power reduction coefficient
0.97
0.95
Minimum and maximum temperature, °C (°F)
Temperature class T5
-25...+85 (-13...+185)
-20...+85 (-4...+185)
-25...+85 (-13...+185)
-20...+85 (-4...+185)
en – Original instructions
Temperature class T4 or T3
-25...+120 (-13...+248)
-20...+90 (-4...+194)
-25...+120 (-13...+248)
-20...+90 (-4...+194)