Table 6- 11
PM230, IP20, Frame Sizes F, 3 AC 380 V ... 480 V
Order No. - without filter
Order No. - with filter
LO base load power
LO base load input current
LO base load output current
HO base load power
HO base load input current
HO base load output current
Fuse according to IEC
Fuse according to UL
Power loss
Required cooling air flow
Cross section of line and motor cables
Tightening torque for line and motor cables
Weight without filter
Weight with filter
Power Module PM230, IP20 / Push-through technology (PT)
Hardware Installation Manual, 06/2014, A5E34331322B AA
6SL3210...
...1NE31-1UL0
6SL3210...
...1NE31-1AL0
55 kW
102 A
110 A
45 kW
84 A
90 A
3NE1224-0
3NE1224-0
1.4 kW
150 l/s
35 ... 120 mm
2 ... 4/0 AWG
13 Nm / 115 lbf in
33 kg
48 kg
6.2 Specific technical data
...1NE31-5UL0
...1NE31-5AL0
75 kW
135 A
145 A
55 kW
102 A
110 A
3NE1225-0
3NE1225-0
1.9 kW
150 l/s
35 ... 120 mm
2
2
2 ... 4/0 AWG
13 Nm / 115 lbf in
33 kg
48 kg