Installation
2.2.3 Orientation
• The direction of the arrow on the nameplate of the measuring device must match the flow
direction of the fluid.
• The following table lists the possible orientations of the measuring devices:
Promass E
2.2.4 Heating
For information on the heating, please see the Operating Instructions on the CD-ROM.
2.2.5 Thermal insulation
For information on the thermal insulation, please see the Operating Instructions on the
CD-ROM.
2.2.6 Inlet and outlet runs
No inlet and outlet runs are required.
2.2.7 Vibrations
No measures are necessary.
6
Vertical
A0004572
Transmitter at the side
Recommended
Horizontal
A0004576
Transmitter at the top
Recommended
This orientation is,
however, not suitable for
fluids with entrained
solids.
Proline Promass 40
Horizontal
A0004576
Transmitter at the bottom
Recommended
This orientation is,
however, not suitable:
• for outgassing fluids
• for low fluid
temperatures.
Endress+Hauser
Need help?
Do you have a question about the Proline Promass 40 and is the answer not in the manual?