ProSoft Technology inRAx MVI56-PDPMV1 User Manual page 145

Profibus dpv1 master
Table of Contents

Advertisement

MVI56-PDPMV1 ♦ ControlLogix Platform
PROFIBUS DPV1 Master
Slave Address
Range 1 to 125, specifies the slave from which to read the configuration.
Error Code [1 ... 4]
If "Return Code" equals 3080h ("Negative indication from lower layer"), status
values according to the DP-specification may be available in "Error Code 1",
Error Codes 2 through 3 are reserved. Refer to Mailbox Messaging Error Codes
(page 135).
Return Code
Refer to Mailbox Messaging Error Codes (page 135).
Fault Information
If "Invalid other" is returned in the Acyclic Message Status Word in the header of
the response, information about the fault can be found here. Refer to Acyclic
Message Status Word (page 135).
0100h: Address out of range.
0A00h: Failed to execute request. Refer to Return Codes (page 136) for
additional information.
0B00h: Remote station failure. Refer to Return Codes (page 136) for additional
information.
FF00h: Module not initialized.
Identifier Bytes [1 ... n]
Refer to EN50170 Vol. 2 for information on the structure of these bytes. In
addition, refer to the documentation provided with the slave device for more
information.
ProSoft Technology, Inc.
November 8, 2010
Mailbox Messaging
User Manual
Page 145 of 235

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the inRAx MVI56-PDPMV1 and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents