Siemens SIRIUS Soft Starter 3RW5 Getting Started page 21

Industrial controls
Table of Contents

Advertisement

Automatic interconnections
By activating "Generate Block Driver" in the "Compile program" dialog as shown in the above
screenshot, interconnections that are not yet available, but that are necessary, will be
automatically executed.
In addition to the interconnections, the driver generator automatically inserts the following
blocks and connects them with the template:
● OB_DIAG1 / OB_DIAG1_PN
● 3RW5Diag
● MOD_SWT
● OR
● AND
Note
To view generated interconnections after executing the driver generator, hit F5 to refresh or
close the CFC and open it again.
Assigning the starting logical address is enough to start the driver generation through which
the
fetched automatically from the HW config.
Download
The CFC-Template is now ready for download.
Go to CPU > Download or hit CTRL+L or use
Template set up is now complete and ready to use.
Remove unused blocks
The following blocks (at CFC Sheet 2 inside the template) are not absolutely necessary for
operating 3RW5 Soft Starters:
● 3RW5Meas
● 3RW5Stat
They provide further functions such as measured values (e.g. temperature) and statistical
data.
These blocks can be deleted (right mouse key → delete or select block → Del). After renewed
compiling and downloading to the PLC, these functionalities are no longer available for the
user program.
SIRIUS Soft Starter 3RW5 PCS 7 Library
Getting Started, 02/2020, A5E48411356002A/RS-AA/001
values are passed to the other dependent blocks, also the
PZDIn03
PZDOut03
in the toolbar.
Getting Started
5.4 CFC
address is
21