Three-Pass Solid Fuel Boiler with Fan Control TOP-W 25-50 KW
INSTRUCTIONS
for usage and maintenance
Prhovačka bb 22310 Šimanovci, Srbija
Tel/Fax. +381 22 480063 +381 63 259422
office@termomont.rs www.termomont.rs
October 20, 2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TOP-W 25 KW and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Termomont TOP-W 25 KW

  • Page 1 Three-Pass Solid Fuel Boiler with Fan Control TOP-W 25-50 KW INSTRUCTIONS for usage and maintenance Prhovačka bb 22310 Šimanovci, Srbija Tel/Fax. +381 22 480063 +381 63 259422 office@termomont.rs www.termomont.rs October 20, 2022...
  • Page 2: Table Of Contents

    Contents 1 Boiler design 1.1 Dimensions ..........1.2 Technical data chart according to EN 303-5 .
  • Page 3: Boiler Design

    Boiler design Parts of the boiler: 1. Combustion chamber 2. Boiler tubes (hot-water) 3. Boiler (water) 4. Flue gas 5. Flow 6. Return 7. Upper door 8. Lower door 9. Water probe 10. Air flue grid 11. Insulation 12. Fill / Drain tap for the boiler (1/2“...
  • Page 4: On Product

    On Product • Prescribed fuel declaration for this boiler is firewood or coal only with caloric value > 15 MJ/kg; • Three-pass solid fuel boiler TOP-W is equipped with fan on the back side and simple regulation unit. It fulfills the requirements of the European norm EN 303/5 (Class 4). •...
  • Page 5: Chimney

    Chimney Boiler connection to the chimney is shown in the figure: Proper dimensioning of the chimney is a very important premise for optimum boiler performance. The purpose of the chimney is to take out the products of combustion but also to secure necessary air draught in the boiler.
  • Page 6: Boiler Installation

    Boiler installation Filling the system with water Filling the system with water is to be done using the tap valve connection of the boiler. When filling the system with water take care that no air remains in the boiler. The filling process is done when no air is coming out through automatic air vent and pressure gauge is showing the value between 1,5 and 2,5 bar (closed systems).
  • Page 7 1) Boiler 2) Boiler valve 3) Automatic air vent 4) Termo-manometer 5) Safety valve 6) Mix valve 7) Expansion vessel 8) Circulation pump 9) Dirt catcher The safety valve (with preset 2,5 bar threshold) should be mounted closed to the boiler (Po- sition 5 at the image above).
  • Page 8: Connecting The Boiler With A Closed Central Heating System With Circulation Pump On The Flow Line

    Connecting the boiler with a closed central heating system with circulation pump on the flow line Recommended connection scheme is depicted below: 1) Boiler 2) Boiler valve 3) Automatic air vent 4) Termo-manometer 5) Safety valve 6) Mix valve 7) Expansion vessel 8) Circulation pump 9) Dirt catcher The safety valve (with preset 2,5 bar threshold) should be mounted closed to the boiler (Po- sition 5 at the image above).
  • Page 9: Boiler Operation

    ratio 1 KW :1 l. Boiler operation Firing with solid fuel First putting into operation is performed exclusively by a skilled person. Before putting in operation please make sure that: • boiler is connected on central heating installation properly • boiler is connected on electric installation properly (when using pellet or oil burner) •...
  • Page 10: Safety Features

    Safety features Thermal safety in case of overheat (closed systems) For hydraulic protection in the closed systems it is necessary to install to safety thermal valve shown on image (to be bought separately, not an integral part of the boiler). If for some reason the temperature of the water inside the boiler should exceed 95°C this valve would release the water from the water supply system to cool down the water temperature inside the boiler.
  • Page 11 Prhovačka bb 22310 Šimanovci, Srbija Tel/Fax. +381 22 480404 +381 63 259422 podrska@termomont.rs www.termomont.rs...