Download Print this page

Danfoss APP 11-13 Instruction Manual page 5

Changing pistons
Hide thumbs Also See for APP 11-13:

Advertisement

Instruction
2.
Assembling
Changing pistons APP 11-13 and APP 16-22
Important: It is essential that the pump is
serviced in conditions of absolute cleanliness.
All parts must be absolute clean before
mounting.
1.
Carefully push the retainer plate in place.
3.
Insert all the pistons randomly.
180R9227 / 521B1194 / DKCFN.PI.013.O1.02 / 03.2012
2.
Ensure that the retainer plate is oriented
correctly with its slant surfaces pointing
downwards.
Note: Tilt the retainer plate for easy insert of
the swash plate. Place pin in the housing.
5

Advertisement

loading
Need help?

Need help?

Do you have a question about the APP 11-13 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

App 16-22