Floor Protection - Regency F2500 Manual

Wood medium stove
Hide thumbs Also See for F2500:
Table of Contents

Advertisement

MINIMUM ALCOVE CLEARANCE AND CLEARANCE TO COMBUSTIBLE
MATERIALS
The Regency Freestanding models have been alcove approved and must be installed
with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 83"
Maximum depth of alcove - 48"
NOTE: This clearance is also required for air space between the appliance and wall/ceiling. Where the
appliance is installed less than 8" from a rear wall, the ember pad only needs to extend to the base of
the wall based on the clearances noted in this manual.
Unit
Medium F2500M with Airmate 15" (381mm)
with Rear Deflector 15" (381mm)

FLOOR PROTECTION

(EMBER PROTECTION ONLY REQUIRED)
A combustible floor must be protected by a non-combustible material (like tile, concrete board, or certified to UL-1618 Type 1 (or as defined by
local codes).
Canada: Beneath the heater and extending to at least 18" on the fuel loading side and at least 8" on the sides and back.
USA: Beneath the heater and extending to at least 16" beyond the fuel loading side and ash removal opening and at least 8" on the sides and back
and under the chimney connector extending 2" beyond each side for horizontal applications.
Minimum Overall Depth (Y) of Floor Protector
Edge of Fuel door
opening to edge
of hearth
Unit
A
F2500
Canada
49" (1245mm)
USA
47" (1194mm)
Minimum Overall Depth (Y) of Floor Protector
Reference only when hearth pad is
installed to rear wall at minimum pipe
clearances.
Residential Installation ''C'' Vent (Single Wall)
Unit
F2500 with Airmate Canada
USA
F2500 with Rear
Canada
Deflector
USA
Residential Close Clearance (To be installed with required pipe components)
Unit
F2500 with Airmate Canada
USA
F2500 with Rear
Canada
Deflector
USA
From Unit
G
H
7" (178mm)
9" (229mm)
Edge of Fuel Door
Opening (Both
Sides)
B
C
18" (457mm) 33 11/16" (856 mm) 8" (203mm)
16" (406mm) 33 11/16" (856 mm) 8" (203mm)
Hearth
Edge of Fuel door
Depth
opening to edge
of hearth
A
B
49-1/2" (1257mm)
18" (457mm)
47-1/2" (1207mm)
16" (406mm)
51-1/2" (1308mm)
18" (457mm)
49-1/2" (1257mm)
16" (406mm)
A
B
48" (1219mm)
18" (457mm)
46" (1168mm)
16" (406mm)
50" (1270mm)
18" (457mm)
48" (1219mm)
16" (406mm)
From Flue Center-Line
I
J
27" (686mm)
13.5" (343mm)
27" (686mm)
15.5" (394mm)
A
D
Hearth
Width
C
33-11/16" (856mm)
33-11/16" (856mm)
33-11/16" (856mm)
33-11/16" (856mm)
C
33-11/16" (856mm)
33-11/16" (856mm)
33-11/16" (856mm)
33-11/16" (856mm)
J
H
G
I
K
16"
405mm
From Wall
K
54" (1372mm)
54" (1372mm)
B
D
D
C
Edge of Fuel Door Opening
(Both Sides)
D
8" (203mm)
8" (203mm)
8" (203mm)
8" (203mm)
D
8" (203mm)
8" (203mm)
8" (203mm)
8" (203mm)
F2500 Wood Stove |
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

F2500-1

Table of Contents