Maintenance; Error Code List - Gree SAPPHIRE SAP12HP230V1AH Installation, Service & Troubleshooting

Hide thumbs Also See for SAPPHIRE SAP12HP230V1AH:
Table of Contents

Advertisement

Service Manual

9. Maintenance

9.1 Error Code List

Malfunction
NO.
Name
High
pressure
1
protection of
system
Anti-freezing
protection for
2
evaporator
Refrigerant
3
leakage
protection
High
discharge
4
temperature
protection of
compressor
Overcurrent
5
protection
Communi-
6
cation
Malfunction
High
temperature
7
resistant
protection
EEPROM
8
malfunction
Limit/
decrease
frequency
9
due to high
temperature
of module
Malfunction
10
protection of
jumper cap
Installation and Maintenance
Display Method of Indoor Unit
Indicator Display (during
blinking, ON 0.5s and OFF
Dual-8
0.5s)
Code
Display
Operation
Cool
Heating
Indicator
Indicator
Indicator
E1
E2
F0
E4
E5
E6
E8
EE
EU
C5
A/C status
During cooling and drying
Possible reasons:
operation, except indoor
1. Refrigerant was superabundant;
fan operates, all loads stop
2. Poor heat exchange (including
operation.
During heating operation, the
and bad radiating environment );
complete unit stops.
Ambient temperature is too high.
Not the error code. It's the
status code for the operation.
1.Refrigerant leakage;
The Dual-8 Code Display will
2.Indoor evaporator temperature
show F0 and the complete unit
stops.
3.The unit has been plugged up
During cooling and drying
operation, compressor and
Please refer to the malfunction
outdoor fan stop while indoor
analysis (discharge protection,
fan operates. During heating
overload).
operation, all loads stop.
During cooling and drying
1. Supply voltage is unstable;
operation, compressor and
2. Supply voltage is too low and
outdoor fan stop while indoor
load is too high;
fan operates. During heating
3. Evaporator is dirty.
operation, all loads stop.
During cooling operation,
compressor stops while
Refer to the corresponding
indoor fan motor operates.
malfunction analysis.
During heating operation, the
complete unit stops.
During cooling operation:
compressor will stop while
Refer to the malfunction analysis
indoor fan will operate.
(overload, high temperature
During heating operation, the
resistant).
complete unit stops.
During cooling and drying
operation, compressor will stop
Replace outdoor control panel AP1
while indoor fan will operate;
During heating operation, the
complete unit will stop
Discharging after the complete unit
is de-energized for 20mins, check
whether the thermal grease on
All loads operate normally,
IPM Module of outdoor control
while
operation frequency for
the radiator is inserted tightly.
compressor is decreased
If its no use, please replace control
panel AP1.
1. No jumper cap insert on
mainboard.
Wireless remote receiver and
2. Incorrect insert of jumper cap.
button are effective, but can
3. Jumper cap damaged.
not dispose the related
4. Abnormal detecting circuit of
command
mainboard.
Possible Causes
sensor works abnormally;
somewhere.
37