Installation

Trigger air supply
1
12
11
Figure 5 Typical Circulating System
1. Pump
2. Heater
3. Filter
4. Solenoid valve

Mounting

Fluid Connections

© 2022 Nordson Corporation

WARNING:
Allow only qualified personnel to perform the following tasks. Follow the
safety instructions in this document and all other related documentation.
Figure 5 shows the fluid and air system for one color of coating material in a typical
installation.
WARNING:

Ground all electrically conductive equipment in the system. Use only
grounded fluid and air hoses.
5
2
8
7
9
10
5. Air regulator
6. Spray gun
7. Ball valves
8. Circulation valve
Slide a 13-mm (1/2-in.) round mounting bar through the holes in the gun module
manifolds, orient the gun as desired, and tighten the square head screws.

WARNING:
In the fluid supply line, install an approved pressure relief device set to the
lowest maximum working pressure of all system components. The fluid hoses must have
a minimum burst pressure greater than the pressure relief device setting.
The spray gun fluid fittings have 1/2- 20 JIC threads. Connect the fluid supply and return
hoses to the fittings. Either fitting can be used for supply or return.
A7A Quattro Modular Automatic Spray Gun
3
7
7
4
6
1/2-20 JIC Fluid Fittings
1/8-in. Trigger Air Fitting
9. Drain off rod
10. Waste container
11. Coating supply
12. Siphon hose and rod
9
1602111-03