2
1
8
1
A/B unit selector key with LED display
Only illumination parameters of the VisiLED unit
(A or B) selected using (1) can be set by the key-
board of the MC 1500! The LED indicators of the
MC 1500 display the settings of the selected unit
only. The illumination is not affected by solely
pressing the selector key.
LED display for segment setting
2
Shows the current segment mode of the selected
illumination unit A/B.
Select key for segment setting
3
Setting of segment mode for selected unit A/B.
LED display for light intensity adjustment
4
Shows the relative brightness of the selected
unit A/B.
Keys for brightness adjustment
5
Keys for increasing/reducing the brightness of the
selected unit A/B. When operating in activated
strobe or trigger mode the keys (5) have special
functions (see Section 7.7).
Key for single step and continuous rotation
6
Single step rotation of the selected unit A/B by
pressing key (6). "On/off" continuous rotation of
selected unit A/B by holding down key (6) for more
than 2 seconds. "On/off" synchronized rotation of
illumination units A and B by pressing or holding
down key combination (10) + (6). Under synchro-
nized rotation the set mixed light characteristics is
retained.
3
4
5
6
9
5
10
7
Memory area
Memory keys M1 to M4 for calling up stored illumi-
nation conditions. Key combination (M) + (M1) to
(M) + (M4) for saving the currently set mixed light.
8
Thermo guard
Red, blinking LED (8) warns of increased tempera-
ture of the illumination unit A or B. When the maxi-
mum permitted temperature is exceeded affected
VisiLED unit is switched off and display (8) is
permanently lit up.
"Strobe" key
9
Activation/deactivation of strobe mode for the
selected illumination unit A/B. Special functions
when strobe mode activated: Key (5): Setting of
strobe frequency; Key combination (10) + (5):
Setting of strobe pulse duration.
10
"Star" key
Only functions when pressed in combination with
other keys.
"Trigger mode" key combination
9
10
Activation/deactivation of trigger mode for the
selected LED unit. Special functions when trigger
mode activated: Key (5): Setting of duration
between external trigger pulse and light pulse.
7
Operating controls
Several special functions like e.g.
flash mode can only be adjusted via
the PC
Subject to modifications and amend-
ments
GB