Download Print this page
Ceco Sethco PMSP-510 Operation Manual

Ceco Sethco PMSP-510 Operation Manual

Self priming and end suction magnetic drive, seal-less pumps

Advertisement

Quick Links

Polypropylene / PVDF
Self Priming and End Suction Magnetic Drive, Seal-less Pumps
O P E R A T I O N
M A N U A L
Self Priming
Models:
PMSP-510
PMSP-525
PMSP-550
KMSP-510
KMSP-525
KMSP-550
End Suction
Models:
PM-510
PM-525
PM-550
KM-510
KM-525
KM-550

Advertisement

loading

Summary of Contents for Ceco Sethco PMSP-510

  • Page 1 Polypropylene / PVDF Self Priming and End Suction Magnetic Drive, Seal-less Pumps O P E R A T I O N M A N U A L Self Priming Models: PMSP-510 PMSP-525 PMSP-550 KMSP-510 KMSP-525 KMSP-550 End Suction Models: PM-510 PM-525 PM-550 KM-510...
  • Page 2 SAFETY RULES FOR SETHCO PUMPS 700 Emlen Way, Telford, PA 18969 Phone: 215-723-8155 Email: infofhs@onececo.com www.cecoenviro.com CONGRATULATIONS! You have just purchased a Sethco Pump, a quality industrial product manufactured to exacting standards. To insure prolonged life of your purchase, please take a few minutes to review the operating instructions and become familiar with the pump.
  • Page 3: Terms And Conditions Of Sale

    700 Emlen Way, Telford, PA 18969 Phone: 215-723-8155 Email: infofhs@onececo.com www.cecoenviro.com TERMS AND CONDITIONS OF SALE The terms and conditions stated acceptance by Sethco cannot be any kind, and the buyer, by accept- below and on the face of any Met canceled without Sethco's written ance of such equipment, assumes Pro Corp., Sethco Div.
  • Page 4 PD-342-02 SELF PRIMING MAGNETIC-DRIVE SEAL-LESS PUMP 700 Emlen Way, Telford, PA 18969 PARTS LIST Phone: 215-723-8155 OPERATION INSTRUCTIONS Email: infofhs@onececo.com www.cecoenviro.com March 1, 2002 SELF PRIMING...MAGNETIC-DRIVE...SEAL-LESS 5 5 0 0 0 0 S S E E R R I I E E S S Models: PMSP-510 PMSP-525 PMSP-550...
  • Page 5 21.7" Max DISCHARGE 21.1" 1" MNPT INLET 1" MNPT 18, 20, 21, 22 Priming 11.8" 9.25" Max Chamber 4-7/8" 9.25 4 24 2 11 O P E R A T I N G I N S T R U C T I O N S INSTALLATION PRIMING AND STARTING Allow sufficient head room and floor space for the addition of priming...
  • Page 6: Parts List

    P A R T S L I S T SETHCO “PMSP/KMSP - 500 SERIES” MAGNETIC-DRIVE, SEAL-LESS SELF PRIMING KMSP MODELS PMSP MODELS ITEM DESCRIPTION QUANTITY MATERIAL PART NUMBER MATERIAL PART NUMBER CASING POLYPRO 133P400368-576 KYNAR 133P400368-383 IMPELLER ————————— SEE TABLE BELOW ———————————— DRIVEN MAGNET —————————...
  • Page 7 A S S E M B L Y / D I S A S S E M B L Y I N S T R U C T I O N S 6. Remove ceramic washer (23) and impeller (2). Inspect both for with base surface.
  • Page 8 FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 5 FIGURE 6...
  • Page 9 FIGURE 7 FIGURE 8 FIGURE 9 FIGURE 10 FIGURE 11 FIGURE 12...
  • Page 10 FIGURE 13 FIGURE 14 FIGURE 16 FIGURE 15...
  • Page 11 PD-342-01 END SUCTION MAGNETIC-DRIVE SEAL-LESS PUMP 700 Emlen Way, Telford, PA 18969 PARTS LIST Phone: 215-723-8155 OPERATION INSTRUCTIONS Email: infofhs@onececo.com March 1, 2002 www.cecoenviro.com END SUCTION...MAGNETIC-DRIVE...SEAL-LESS 5 5 0 0 0 0 S S E E R R I I E E S S Models: PM-510 PM-525...
  • Page 12: Installation

    8.6" DISCHARGE 1" MNPT 9-1/4" 4-7/8" INLET 1" MNPT 8" 3-1/2" 11, 12 16.5" Max O P E R A T I N G I N S T R U C T I O N S INSTALLATION 2. Turn switch "on" and then "off" immediately. Observe rotation.
  • Page 13 P A R T S L I S T SETHCO “PM/KM - 500 SERIES” MAGNETIC-DRIVE, SEAL-LESS END SUCTION PUMP PM MODELS KM MODELS ITEM DESCRIPTION QUANTITY MATERIAL PART NUMBER MATERIAL PART NUMBER CASING POLYPRO 133P400368-576 KYNAR 133P400368-383 IMPELLER ————————— SEE TABLE BELOW ———————————— DRIVEN MAGNET —————————...
  • Page 14 A S S E M B L Y / D I S A S S E M B L Y I N S T R U C T I O N S You will need the following tools: 12. Locate so that cup pilot seats into adapter pilot and all 1.
  • Page 15 FIGURE 1 FIGURE 2 FIGURE 3 FIGURE 4 FIGURE 5 FIGURE 6...
  • Page 16 FIGURE 7 FIGURE 8 FIGURE 9...