Lora D2Dsettings - LINOVISION IOT-S500DCS Quick Start Manual

Lorawan@ magnet contact switch
Hide thumbs Also See for IOT-S500DCS:
Table of Contents

Advertisement

tamper button is activated.
Enable or disable the light indicating in chapter 2.3.
LED Indicator
Note: The indicator of reset button is not allowed to disable.
Change Password
Change the password for ToolBox App to write this device.

3.4LoRa D2DSettings

LoRa D2D protocol is developed by Linovision and used for setting up transmission
among Linovision devices without gateway. When the LoRa D2D setting is enabled, IOT
S500DCScan work as a LoRa D2D controller to send control commands to trigger LoRa
D2Dagent devices.
1. Enable LoRa D2Dfeature.
2. Define a unique LoRa D2D key which is the same as LoRa D2D agent devices, then s
elect the frequency and spreading factor. (Default LoRa D2D Key: 5572404C696E6B4C6F5
2613230313823)
3. Enable one of IOT-S500DCS status and configure a 2-bytehexadecimal command (This
command is pre-definedin LoRa D2D agent device). When IOT-S500DCS detects this
status, it will send the control command to corresponding LoRa D2Dagent devices.
Note: When this feature is enabled, the device will not send data to LoRaWAN
IOT-S500DCS magnet status changes.
®
network server if