Sensor Data; Downlinkcommands - LINOVISION IOT-S500DCS Quick Start Manual

Lorawan@ magnet contact switch
Hide thumbs Also See for IOT-S500DCS:
Table of Contents

Advertisement

5.2 Sensor Data

IOT-S500DCS reports open/close status and tamper status as follows:
According to reporting interval;
When magnet or tamper status has changed.
Channel
01
03
04
Example:
Channel
Type
75
01
(Battery)
Channel
Type
00
04
(Tamper
Status)
5.3 Downlink Commands
IOT-S500DCS supports downlinkcommands to configure the device. The application port
is 85 by default.
Channel
ff
Example: Set reporting interval as 20 minutes.
Channel
ff
Type
75(Battery Level)
UINT8, Unit: %
00=>Switchclose
00(Magnet Status)
01=>Switch open
00=>Deviceis installed
00(Tamper Status)
01=>Deviceis un-installed
01 75 64 03 00 00 04 00 01
Value
64 =>100%
Value
01
(Un-installed)
Type
03 (Set Reporting Interval)
ff03b004
Type
03 (Set Reporting
Interval)
-END-