2. Installation Instruction
• Connect the power cable as shown in the
wiring diagram (see chapter "Specification /
Wiring diagram").

5. Commissioning

5.1 Initial start-up

• Fill the appliance by running the tap several
times until the pipework and appliance are
free of air.
• Carry out a tightness check.
• Insert the power cable plug, if present, into
the standard safety socket or set the fuse/
MCB.
• Check the function of the appliance.
• In the case of oversink installation, affix the
company logo supplied over the existing
company logo.

5.2 Appliance handover

• Explain the appliance function to users and
familiarise them with its operation.
• Make users aware of potential dangers,
especially the risk of scalding.
• Hand over these instructions.

5.3 Recommissioning

Material losses
!
Following an interruption of the
water supply, recommission the appliance
by carrying out the following steps, in order
to prevent irreparable damage to the bare
wire heating system.
12
for the qualified installer
• Isolate the appliance from the power supply.
Pull the power cable plug, if present, from
the socket, or remove the fuse/reset the
MCB (Miniature Circuit Breaker in the house
installation)..
• See chapter "Initial start-up".

5.4 Settings

You can alter the maximum flow rate and
temperature.
DANGER Electrocution
The flow rate and temperature may
only be adjusted if the appliance is isolated
from the power supply.
• Isolate all poles of the appliance from the
power supply.
DANGER Electrocution
The adjusting screw for changing the
flow rate and the potentiometer for setting
the temperature are live if the appliance has
not been isolated from the power supply.
• Remove the appliance cover.
Setting the maximum temperature
Factory setting: 50 °C