Meinberg LANTIME M300 Manual

Meinberg LANTIME M300 Manual

Ntp server
Hide thumbs Also See for LANTIME M300:
Table of Contents

Advertisement

Quick Links

MANUAL
LANTIME M300/GPS
NTP Server

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LANTIME M300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Meinberg LANTIME M300

  • Page 1 MANUAL LANTIME M300/GPS NTP Server...
  • Page 3: Table Of Contents

    Table of Contents 1 Impressum 2 Quick Start 3 Network Timeserver with GPS synchronized time base 4 The Modular System LANTIME 5 Network Time Protocol (NTP) 6 GPS satellite controlled clock 7 Mounting the GPS Antenna 8 Booting the GPS receiver 9 Booting the Single Board Computer 10 Configuration User Interface...
  • Page 4 11 The graphical user interfaces 12 The WEB Interface...
  • Page 5 13 The Command Line Interface 14 SNMP Support 15 Attachment: Technical Information...
  • Page 7: Impressum

    1 Impressum...
  • Page 8: Quick Start

    2 Quick Start...
  • Page 9: Network Timeserver With Gps Synchronized Time Base

    3 Network Timeserver with GPS synchronized time base...
  • Page 10: The Modular System Lantime

    4 The Modular System LANTIME...
  • Page 11 4.1 Supported Network Services 4.2 Additional Features 4.3 User Interface...
  • Page 12 4.4 Options 4.5 Why to use a Network Time Server?
  • Page 13: Network Time Protocol (Ntp)

    5 Network Time Protocol (NTP) 5.1 NTP Target 5.2 NTP-Client Installation...
  • Page 14 remote refid when poll reach delay offset ji�er ======================================================================= LOCAL(0) LOCAL(0) 0.00 0.000 7885 lan�me .GPS. 0.00 60.1 15875...
  • Page 15: Gps Satellite Controlled Clock

    6 GPS satellite controlled clock 6.1 GPS170 Features 6.2 Time Zone and Daylight Saving...
  • Page 16: Mounting The Gps Antenna

    7 Mounting the GPS Antenna 7.1 Example:...
  • Page 17 7.2 Antenna Short-Circuit Assembly with surge voltage protection...
  • Page 18 7.3 Antenna Short-Circuit...
  • Page 19: Booting The Gps Receiver

    8 Booting the GPS receiver...
  • Page 20: Booting The Single Board Computer

    9 Booting the Single Board Computer...
  • Page 21: Configuration User Interface

    10 Configuration User Interface 10.1 Introduction: Configuration LANTIME...
  • Page 22 10.2 Root Menu Ref. Time Time Service Network Alarm...
  • Page 23 GPS: NORMAL OPERATION Thu, XX.XX.XXXX NTP: Offs. GPS: 2us 14:00:00 -> Reference Time <- Network Time Service System -> Setup GPS <- Setup Outputs Info GPS Reference Time Network -> Time Service <- System -> external NTP <- Restart NTP Local Stratum Reference Time ->...
  • Page 24 10.3 Men ¨ u : Reference Time 10.3.1 Setup GPS Receiver Parameters 10.3.2 Set Antenna Cable Length 10.3.3 Set GPS Receiver Simulation Mode...
  • Page 25 10.3.4 Init GPS Receiver 10.3.5 Initiate Cold Boot of GPS Receiver 10.3.6 Initiate Warm Boot of GPS Receiver 10.3.7 Init GPS Position 10.3.8 Init GPS Time...
  • Page 26 10.3.9 Info GPS 10.3.10 GPS Status 10.3.11 GPS Version 10.3.12 GPS Receiver Position 10.3.13 GPS Satellite Constallation...
  • Page 27 10.3.14 Setup GPS Outputs 10.3.15 GPS Enable Outputs 10.3.16 Serial Outputs...
  • Page 28 10.3.17 Setup Time Zone of Serial Outputs...
  • Page 29 10.4 Menu: Time Service 10.4.1 Menu: external NTP 10.4.2 Menu: Stratum of local clock 10.4.3 Menu: Restart NTP...
  • Page 30 10.5 Programmable pulse (Option) 10.5.1 SETUP POUT X Programmable Pulses: Out1:Pulse Per Se.. Out2: Pulse Per Sec Out3:Pulse Per Se.. Select Output Programmable Pulses Output Select Output Programmable Pulses Output Select Output 1 --> Mode <-- Holdover Select Output 2 -->...
  • Page 31 10.5.2 Mode 10.5.3 Cyclic Pulse POUT1 CYCLIC: active:low TIME: 00:00:02 Length: 00.10 sec 10.5.4 Single Shot POUT1 SINGLE: active:low TIME: 12:00:00 Length: 00.10 sec 10.5.5 Timer mode Select Output 1 TIMER 1 POUT1 TIMER1: active:low ON: 10:50:00 OFF: 11:00:00 POUT1 TIMER2: active:low ON: 10:50:00 OFF: 11:00:00...
  • Page 32: Time Sync

    10.5.6 Idle mode Setup Output 1 diable Output Press OK to confirm X 10.5.7 Position OK / TimeSync / AllSync Position OK Setup Output 1 Mode: Position OK POUT1 POS OK: Position ok active: high Time Sync Setup Output 1 Mode: Time Sync POUT1 TimeSync: active: high...
  • Page 33 10.5.8 DCF Mark Setup Output 1 Mode: DCF77 Marks POUT1 DCF77: active: high Timeout: 00 10.5.9 PPS, PPM, PPH Modes POUT1 Pulse Per Sec (PPS): output active:low LNG: 00.10 sec POUT1 Pulse Per Min (PPM): output active:low LNG: 00.10 sec POUT1 Pulse Per Hour (PPH): output active:low LNG: 00.10 sec...
  • Page 34 10.6 Menu: Synthesizer Frequency Output 10.7 Menu: TIME CODE IRIG...
  • Page 35 10.8 Menu: Network 10.8.1 Setup Global Configuration...
  • Page 36 10.8.2 Setup Network Interfaces 10.8.3 Setup Network Ipv4 Parameter...
  • Page 37 10.8.4 Menu: Setup Ipv6 Parameter 10.8.5 Menu: Link Mode 10.8.6 Menu: Setup Network Services 10.9 Menu: System Reference Time Network Time Service -> System <- ->Set Time Zone<- Restart Menu Factory Defaults...
  • Page 38 10.9.1 Set time zone...
  • Page 39 10.9.2 Restart Menu Set Time Zone -> Restart Menu <- Factory Defaults -> Reboot Time Server <- Restart NTP...
  • Page 40 11 The graphical user interfaces...
  • Page 41 12 The WEB Interface...
  • Page 42 12.1 Configuration: Main Menu...
  • Page 43 12.2 Configuration: Ethernet...
  • Page 44 12.2.1 SYSLOG Server...
  • Page 45 12.3 Network interface specific configuration 12.3.1 IPv4 addresses and DHCP 12.3.2 IPv6 addresses and autoconf...
  • Page 46 12.3.3 High Availability Bonding...
  • Page 47 12.3.4 Additional Network Configuration...
  • Page 48 12.4 Configuration: Notification...
  • Page 49 12.4.1 Alarm Events...
  • Page 50 12.4.2 E-mail messages 12.4.3 Windows Popup Messages 12.4.4 SNMP-TRAP messages 12.4.5 VP100/NET wall mount display 12.4.6 User defined Alarm scripts...
  • Page 51 12.4.7 NTP Client Monitoring 12.4.8 Alarm messages...
  • Page 52 12.5 Configuration: Security...
  • Page 53 12.5.1 Password 12.5.2 HTTP Access Control 12.5.3 SSH Secure Shell Login...
  • Page 55 12.5.4 Generate SSL Certificate for HTTPS...
  • Page 56 12.5.5 NTP keys and certificates 12.5.6 SNMP Parameter...
  • Page 57 12.6 Configuration: NTP...
  • Page 59 12.6.1 NTP Authentication...
  • Page 60 12.6.2 NTP AUTOKEY...
  • Page 63 12.7 Configuration: Local...
  • Page 64 12.7.1 Administrative functions 12.7.2 User Management...
  • Page 65 12.7.3 Administrative Information...
  • Page 67 12.7.4 Software Update...
  • Page 68 12.7.5 Automatic configuration check 12.7.6 Get Diagnostics Information...
  • Page 69 12.7.7 Receiver Information 12.7.8 Web interface language...
  • Page 70 12.8 Configuration: Statistics...
  • Page 71 12.8.1 Statistical Information...
  • Page 72 12.9 Configuration: Manual...
  • Page 73 12.10 Configuration: PTP...
  • Page 74 12.10.1 PTPv2 - Global Configuration...
  • Page 75 12.10.2 PTP Network Configuration...
  • Page 76 12.10.3 PTP State Files...
  • Page 77 13 The Command Line Interface...
  • Page 78 13.1 CLI Ethernet...
  • Page 80 13.2 CLI Notification...
  • Page 82 13.3 CLI Security...
  • Page 84 13.4 CLI NTP Parameter...
  • Page 85 13.4.1 CLI NTP Authentication 13.5 CLI Local...
  • Page 88 14 SNMP Support...
  • Page 89 14.1 Configuration over SNMP 14.1.1 Examples for the usage of the SNMP configuration features...
  • Page 90 14.1.2 Further configuration possibilities 14.1.3 Send special timeserver commands with SNMP...
  • Page 92 14.1.4 Configuration of the timeserver with SNMP: Reference...
  • Page 96 14.2 SNMP Traps...
  • Page 97 14.2.1 SNMP Trap Reference...
  • Page 98 15 Attachment: Technical Information 15.1 Skilled/Service-Personnel only: Replacing the Lithium Battery...
  • Page 99 15.2 Technical Specifications M600/300 Multipac DC Input 100 - 240 VDC 12 VDC 24 VDC 48 VDC...
  • Page 100 15.3 Safety instructions for building-in equipment 15.3.1 CE-Label...
  • Page 101 15.4 Front and Rear Panel Connectors...
  • Page 102 15.5 Pin Assignment: Serial Connectors 15.5.1 Serial Time String 15.5.2 TERMINAL (Console) -DCD_IN DSR_IN - -RXD_IN RTS_OUT- -TXD_OUT CTS_IN- -DTR_OUT RI_IN- -GND TERM...
  • Page 103 15.6 Error Relay 15.6.1 Technical Specification Normal Operation: CO - NO connected Error Error: CO - NC connected CO NO NC Error...
  • Page 104 15.7 Technical Specifications GPS receiver...
  • Page 105 15.7.1 Oscillator specifications...
  • Page 106 15.7.2 Technical Specifications GPS Antenna...
  • Page 107 15.8 Technical Specifications LAN CPU...
  • Page 108 15.9 Time Code 15.9.1 Abstract of Time Code 15.9.2 Principle of Operation 15.9.3 Block Diagram Time Code...
  • Page 109 15.9.4 IRIG Standard Format...
  • Page 110 15.9.5 AFNOR Standard Format...
  • Page 111 15.9.6 Assignment of CF Segment in IEEE1344 Code...
  • Page 112 15.9.7 Generated Time Codes 15.9.8 Selection of Generated Time Code 15.9.9 Outputs...
  • Page 113 AM - Sine Wave Output DCLS Output 15.9.10 Technical Data...
  • Page 114 15.10 Time Strings 15.10.1 Format of the Meinberg Standard Time String...
  • Page 115 15.10.2 Format of the Meinberg GPS Time String...
  • Page 116 15.10.3 Format of the Meinberg Capture String...
  • Page 117 15.10.4 Format of the SAT Time String...
  • Page 118 15.10.5 Format of the Uni Erlangen String (NTP)
  • Page 120 15.10.6 Format of the NMEA 0183 String (RMC)
  • Page 121 15.10.7 Format of the NMEA 0183 String (GGA)
  • Page 122 15.10.8 Format of the NMEA 0183 String (ZDA)
  • Page 123 15.10.9 Format of the ABB SPA Time String...
  • Page 124 15.10.10 Format of the Computime Time String...
  • Page 125 15.10.11 Format of the RACAL standard Time String...
  • Page 126 15.10.12 Format of the SYSPLEX-1 Time String...
  • Page 127 15.10.13 Format of the ION Time String...
  • Page 128 15.11 Manual VP100/NET Display configuration...
  • Page 129 15.12 Global Configuration File...
  • Page 131 15.13 Global Option File 15.14 Third party software 15.14.1 Operating System GNU/Linux 15.14.2 Samba...
  • Page 132 15.14.3 Network Time Protocol Version 4 (NTP) 15.14.4 mini httpd...
  • Page 133 15.14.5 GNU General Public License (GPL)
  • Page 137 15.15 USB Stick 15.15.1 Menu Backup Configuration to USB Stick 15.15.2 Menu Write Diagnostic File to USB Stick...
  • Page 138 15.15.3 Keypad locking 15.15.4 Menu Restore Configuration...
  • Page 139 15.16 Reference...
  • Page 140 Konformitätserklärung Declaration of Conformity Hersteller Meinberg Funkuhren GmbH & Co. KG Lange Wand 9 Manufacturer D-31812 Bad Pyrmont erklärt in alleiniger Verantwortung, daß das Produkt declares under its sole responsibility, that the product NTP Timeserver Produktbezeichnung Product Name Lantime M300/GPS...

This manual is also suitable for:

Lantime m300/gps

Table of Contents

Save PDF