correct sizing of the switch or plug, refer to the absorbed current specified on the
appliance data plate (32A).
• If the power cable is damaged, it must be replaced by the Customer Care Service or in
any case by specialised personnel, in order to prevent any risk.
• Verify that a safety circuit breaker is installed between the power cable of the appliance
and the mains electric line. The contact opening max. distance and leakage current
must comply with the local safety regulations.
• After making the connection, with the appliance running check that the power supply
does not fluctuate by ±10% the rated voltage.
• Be sure to power the equipment with systems that are protected against overvoltage;
the manufacturer declines all responsibility for effects due to anomalies induced by the
electrical supply system.
• The machine that can operate at 50 or 60 Hz does not need any setting by the user.
Electrical connection for appliances with plug
• To connect to the power supply, insert the power cable plug in the corresponding mains
socket, first making sure:
• the socket has an efficient earth contact and the mains voltage and frequency match
that given on the dataplate. In case of any doubts regarding the efficiency of the earth
connection have the system checked by specialised personnel;
• the system power supply is arranged and able to take the actual current absorption and
that it is correctly executed according to the regulations in force in the country of use;
• The plug must be accessible after positioning the appliance in the place of installation;
• The plug must be in a position always visible to the operator performing the intervention
during maintenance operations;
Electrical connection for appliances with cable without plug
• The connection point has an efficient earth contact and the mains voltage and frequency
match that given on the data plate. In case of doubts regarding the efficiency of the earth
wire, have the system checked by specialised personnel;
• the appliance must be permanently connected to the power supply, respecting the
polarities:
– brown/black/gray: phase
– yellow/green: earth
– blue: neutral;
• An H07RN-F type power cable (code 60245 IEC 66) is used for the permanent
connection to the mains; in case of replacement, use a type with at least these
characteristics. When replacing the cable, the earth wire must be kept longer than the
live and neutral wires.
• The differential thermal-magnetic switch must be lockable in the open position in case of
maintenance.
• If using a plug, it must comply with the national installation rules. The plug must also be:
– accessible after the appliance has been positioned
– in the place of installation;
– in a position always visible to the operator performing the intervention during
maintenance operations;
A.8

General safety rules

Do not use gas cooking units and do not flambé, as this can be dangerous.
10

Advertisement

Table of Contents
loading