CAUTION
Before moving the appliance make sure
the load bearing capacity of the lifting
equipment used is suitable for its weight.
F.2

Customer's responsibilities

The tasks and works required of the Customer are:
• prearrange a high-sensitivity manual-reset magneto-ther-
mal circuit-breaker;
• prearrange a device lockable in the open position for the
connection to the power supply.
• check the floor planarity on which the machine is placed.
• for information regarding the electrical connection, refer to
F.4.1 Electrical appliances paragraph;
F.3

Connections introduction

• Any installation work or maintenance to the supply system
must only be carried out by the utility company or an
authorised installation technician.
• Refer to the appliance dataplate for the product code.
• See the installation diagram for the type and position of
appliance connections.
F.4

Electrical connection

F.4.1

Electrical appliances

WARNING
Work on the electrical systems
must only be carried out by
specialised personnel.
IMPORTANT
Connection to the power supply must be carried out
in compliance with the regulations and provisions in
force in the country of use.
For connection, just insert the power cable plug in the
corresponding electrical system socket, firstly making sure:
1. The socket has an efficient earth connection and the
mains frequency matches that given on the dataplate. In
case of any doubts regarding the efficiency of the earth
connection have the system checked by qualified
personnel.
G
NORMAL MACHINE USE
WARNING
Refer to "WARNING and Safety
Information"
G.1
Characteristics of personnel trained for
normal machine use
The Customer must make sure the personnel for normal
machine use are adequately trained and skilled in their duties,
as well as ensuring their own safety and that of other persons.
The Customer must make sure his personnel have understood
the instructions received and in particular those regarding work
hygiene and safety in use of the machine.
G.2
Characteristics of personnel enabled to
operate on the machine
The Customer is responsible for ensuring that persons
assigned to the various duties:
• read and understand the manual;
• receive adequate training and instruction for their duties in
order to perform them safely;
2. The system power supply is arranged and able to take the
actual current absorption and that it is correctly executed
according to the regulations in force in the country of use.
3. A differential thermal-magnetic switch suitable for the
input specified on the dataplate, with contact gap enabling
complete disconnection in category III overvoltage con-
ditions and complying with the regulations in force, is
installed between the power cable and the electric line.
For the correct size of the switch, refer to the absorbed
current specified on the appliance dataplate (32A).
4. After making the connection, with the appliance working
check that the power supply does not fluctuate by ±10%
the rated voltage.
IMPORTANT
The plug must also be:
accessible after the appliance has been positioned
in the place of installation;
in a position always visible to the operator perform-
ing the intervention during maintenance operations.
WARNING
If the power cable is damaged, it
must be replaced by the service
centre or in any case by qualified
personnel, in order prevent any
risk.
The manufacturer declines any liability for damage or injury
resulting from breach of the above rules or non-compliance
with the electrical safety regulations in force in the country
where the machine is used.
F.4.2

Circuit breaker

Verify that a safety circuit breaker is installed between the
power cable of the appliance and the mains electric line.
The contact opening max. distance and leakage current must
comply with the local safety regulations.
F.4.3

Equipotential node and Earth connection

Connect the appliance to an earth; it must be included in an
equipotential node by means of the screw located under the
frame.
The screw is marked with the symbol
• receive specific training for correct machine use.
G.3
Operator qualified for normal machine
use
Must have at least:
• knowledge of the technology and specific experience in
operating the machine;
• adequate general basic education and technical knowledge
for reading and understanding the contents of the manual,
including correct interpretation of the drawings, signs and
pictograms;
• sufficient technical knowledge for safely performing his
duties as specified in the manual;
• knowledge of the regulations on work hygiene and safety.
In case of a significant anomaly (e. g. short circuits, wires
coming out of the terminal block, motor breakdowns, worn
electrical cable sheathing, etc.) the operator for normal
machine use must:
• immediately deactivate the machine and disconnect all the
supplies (electricity, gas, water).
.