4. Draining And Flushing The Reservoir
Drain, clean and replenish the reservoir with high-grade, approved Power Team hydraulic fluid yearly or
more often if necessary. The frequency of fluid change will depend upon the general working conditions,
severity of use and overall cleanliness and care given the pump�
IMPORTANT:
Clean the exterior of the pump first. After draining and flushing the reservoir, drain and clean the other
hydraulic system components (hoses, cylinders, etc.) before connecting them to the pump again. This
will help prevent contaminated fluid from entering the pump.
Refer to Table 1 for your reservoir type.
For models with Reservoir Type A:
A�
Unthread and separate the pump head from the reservoir� Drain the reservoir of the used hydraulic
fluid.
B�
Flush out reservoir with a small amount of clean hydraulic fluid. Clean the pump intake filter.
IMPORTANT:
Removing the filter from the pump assembly could result in its breakage. Attempt to clean it as well as
possible with it installed.
C� Refill the reservoir and reassemble the pump head to the reservoir. Tighten securely. Check for leaks.
For models with Reservoir Type B & C:
A� Remove the filler cap. Drain the hydraulic fluid through filler hole.
B� Remove the nut from the tie rod� Separate the reservoir from the pump body� Clean the reservoir and
filter.
IMPORTANT:
Removing the filter from the pump assembly could result in its breakage. Attempt to clean it as well as
possible with it installed.
C� Reassemble and fill the reservoir with Power Team hydraulic fluid. Replace the filler cap.
For models with Reservoir Type D:
A� Remove the ten screws fastening the reservoir cover to the reservoir, and lift the pump and valve as-
semblies off�
B� Drain all hydraulic fluid and flush reservoir with a small amount of clean hydraulic fluid.
C� Remove the pump assembly filter, rinse it clean, and reassemble.
D� Refill the reservoir with Power Team hydraulic fluid. Place the pump and valve assembly (with gasket)
on the reservoir, and thread the ten screws. Tighten securely and evenly.