Linear m&s VMC1 Instructions Manual page 7

Video security intercom system
Hide thumbs Also See for m&s VMC1:
Table of Contents

Advertisement

VMC1 Master Terminations
VDC IN 13.8V
0V - Input from TE6D
power unit
INTERCOM
(Figure 4)
POS
NEG
TC
VLC
VLC1
VLC2
VLC3
SHLD
COM1
FROM
DOOR
STATION
MATCH
WIRE COLORS
ON EACH TERMINAL
USE WOOD SCREWS
TO SECURE TERMINAL
BLOCK TO STRUCTURE
Connect red wire from TE6D Power Supply (
Connect black wire from TE6D Power Supply
Connects to Corresponding terminal at Room and Door stations
(Green White from terminal block)
Connects to Corresponding terminal at Room and Door stations
(Green from terminal block)
Connects to Corresponding terminal at Room and Door stations
(Orange White from terminal block)
Connects to Corresponding terminal at Room stations only
(Orange from terminal block)
Connects to VLC terminal at Door station 1
(Orange from Video Door Station)
Connects to VLC terminal at Door station 2
(Orange from Video Door Station)
Connects to VLC terminal at Door station 3
(Orange from Video Door Station)
Not Connected (except where shielded cable used)
Connects to Corresponding terminal at Room and Door stations
(Blue White from terminal block)
USE TERMINAL BLOCK TO COMBINE CAT-5 CABLES FROM STATIONS
FROM
ROOM
STATION
GRN/WHT GRN ORG/WHT ORG
CAT5 to Master Station
Figure 3
FROM
ROOM
STATION
BLU/WHT
BLU
BRN/WHT
Master Station
See Figure 4)
FROM
ROOM
FROM
STATION
NIGHTSTAND
STATION
8-POSITION
TERMINAL
BLOCK
BRN
7