VMC1 Master Terminations
CAM PWR (See Figure 5)
12V & 0V
Regulated 12V output for powering stand-alone cameras (See Figure 5)
CAM 1
VID1
Video Signal from door station 1 camera (coax center or Brown White on CAT5) or other
analog NTSC video device
GND
Video GND from camera on Door Station 1 (Coax Ground or Brown on CAT5) or other
analog NTSC video device
CAM 2
VID2
Video Signal from door station 2 camera (Coax Center or Brown White on CAT5) or other
analog NTSC video device
GND
Video GND from camera on door station 2 (Coax Ground or Brown on CAT5) or analog
NTSC device
CAM 3
VID3
VID3 - Video Signal from door station 3 camera (Coax Center or Brown White on CAT5)
or other analog NTSC video device
GND
Video GND from camera on door station 3 (Coax Ground or Brown on CAT5 Brown) or
other analog NTSC video device
ALL AC ELECTRICAL CONNECTIONS TO THE POWER SOURCE TE6D POWER SUPPLY MUST BE MADE BY A LICENSED ELECTRICIAN AND
MUST OBSERVE ALL NATIONAL AND LOCAL ELECTRICAL CODES
Figure 5