Summary of Contents for INOXPA NHS VERTICAL AGITATOR Ex
Page 1
MAINTENANCE INSTRUCTIONS ANNEX FOR CE MARKED EQUIPMENT ACCORDING TO THE ATEX DIRECTIVE 2014/34/EU: NHS VERTICAL AGITATOR Ex The content of this Annex supplements the information in the instruction manual. The instructions in this Annex must be taken into account in conjunction with the equipment marked according to Directive 2014/34/EU.
Page 2
20.050.30.06EN (A) 2022/10 EU Declaration of Conformity INOXPA, S.A.U. Telers, 60 17820 - Banyoles (Girona) Hereby declare under Our sole responsibility that the machine VERTICAL AGITATOR Model From serial number IXXXXXXXXX to IXXXXXXXXX is in compliance with all applicable provisions of the following directive:...
1.4. WARRANTY Any warranty will be void immediately and lawfully and, in addition, INOXPA shall be compensated for any product liability claims submitted by third parties in the case of non-compliance with any of the indications given in the attached annex or in...
Page 4
The agitator was selected for use in explosive atmospheres at the time of placing the order, according to ATEX form. INOXPA is not liable for any damage that may arise if the information provided by the buyer is incomplete or incorrect (liquid type, viscosity, RPM, classification of the potentially explosive area, gas generated by the potentially explosive atmosphere, etc.)
C Db Figure 1.1.: ATEX CE marking on the nameplate. Should the marking on the machine not correspond with the order, please contact INOXPA immediately to explain the situation. The temperature class and the maximum surface temperature depend on the temperature of the product to be stirred and the ambient temperature.
The agitator was selected for use in explosive atmospheres at the time of placing the order, according to ATEX form. INOXPA is not liable for any damage that may arise if the information provided by the buyer is incomplete or incorrect (liquid type, viscosity, RPM, classification of the potentially explosive area, gas...
4. Installation and assembly 4.1. INSTALLATION AND ASSEMBLY ATEX agitators are very compact machines and are always supplied together with the drive 4.2. INSTALLATION SITE It is very important to be able to access the electrical wiring and connections on the agitator, even when it is in operation. Please be aware that while handling any equipment with an electrical connection, a potentially explosive atmosphere may be present, and for this reason safe work permits should be issued Some type of air recirculation for cooling the gear motor on the agitator must be provided.
Page 9
In addition, overload protections suitable for the gear motor power rating must be installed on the gear motor...
5. Start-up, operation and shutdown 5.1. START-UP Explosive atmospheres may be generated during the start-up of the agitator, and safe work permits should be issued for this purpose. These tasks shall only be carried out by qualified or trained personnel 5.2.
ATEX agitator and include the manufacturing number. If the spare parts are not requested in this way, Inoxpa shall not be responsible for the case that the agitator may not operate with parts which are not suitable for the classified zone where is installed.
Incorrect assembly or disassembly may cause the agitator to malfunction and lead to high repair costs and a long down-time period, even invalidating the system's protection systems. INOXPA is not responsible for accidents or damages caused by failure to comply with the instruction manual and with this annex.
Need help?
Do you have a question about the NHS VERTICAL AGITATOR Ex and is the answer not in the manual?
Questions and answers