Advertisement

Quick Links

INSTALLATION, SERVICE AND MAINTENANCE
ANNEX FOR CE ATEX REGISTERED EQUIPMENT UNDER DIRECTIVE
KIBER KSF Ex / KIBER KSFT Ex
The contents of this Annex complement the information included in the instruction manual.
The instructions in this Annex must be observed whenever equipment registered under
Directive 2014/34/EU is used.
This annex is to be added to the manuals of the ATEX-certified components that form part
of the assembly (e.g. motors, etc).
INSTRUCTIONS
2014/34/UE:
INOXPA, S.A.U.
Telers, 60
17820-Banyoles
Tel.: +34 972 57 52 00
Fax: +34 972 57 55 02
inoxpa@inoxpa.com
www.inoxpa.com
Manual Original
01.611.30.11EN
(0) 2022/06

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the KIBER KSF Ex and is the answer not in the manual?

Questions and answers

Summary of Contents for INOXPA KIBER KSF Ex

  • Page 1 ANNEX FOR CE ATEX REGISTERED EQUIPMENT UNDER DIRECTIVE 2014/34/UE: KIBER KSF Ex / KIBER KSFT Ex The contents of this Annex complement the information included in the instruction manual. The instructions in this Annex must be observed whenever equipment registered under Directive 2014/34/EU is used.
  • Page 2 01.611.30.12EN (0) 2022/11 EU Declaration of Conformity INOXPA, S.A.U. Telers, 60 17820 – Banyoles (Girona) Hereby declare under our sole responsibility that the machine HELICOIDAL PUMP Designation KIBER Type KSF - KSFT IXXXXXXXXX IXXXXXXXXX From serial number Is in compliance with applicable provisions of the following directive:...
  • Page 3: Safety

    The limits of the operating conditions in explosive atmospheres must not be exceeded. This pump was selected according to the operating conditions specified by the user. Therefore, INOXPA disclaims liability for any damage caused by use of the pump in conditions other than those stated in the order. 1.3.3. During maintenance Danger! Important indications regarding protection from explosions An explosive atmosphere may be created during disassembly of the pump.
  • Page 4 RESPONSIBILITY FOR THE ATEX CERTIFICATION If INOXPA, S.A.U supplies a bare shaft pump, the certification mark for protection from explosion only relates to the pump. All assembled equipment must have separate certification supplied by the equipment manufacturer and should have at least the same protection grade or one protection grade more than the pump.
  • Page 5: Table Of Contents

    2. Table of Contents 1. SAFETY ............................2 1.1. Instructions for starting up ....................2 1.2. Safety ..........................2 1.3. General safety instructions ....................2 2. TABLE OF CONTENTS ........................4 3. GENERAL INFORMATION ......................5 3.1. Description ........................5 3.2.
  • Page 6: General Information

    3. General information 3.1. DESCRIPTION For the helical pumps of the KIBER KSF Ex / KIBER KSFT Ex series, the motors must be appropriate for working in explosive atmospheres. 3.2. APPLICATION This pump was selected for a given set of pumping conditions and operating conditions in explosive atmospheres when the order was placed.
  • Page 7: Installation

    C Db CE ATEX mark inscribed on the manufacturer’s plate. If the equipment mark does not correspond to the order, INOXPA should be immediately informed of the situation. The temperature class and the maximum surface temperature depend on the temperature of the product to be pumped and the ambient temperature.
  • Page 8: Pipes

    The motors used must be EC marked in accordance with Directive ATEX 2014/34/EU and with the instructions of the manufacturer and the applicable national and local regulations. When pumping inflammable or explosive liquids, a proper connection must be used. Connect the parts of the assembly with the earth connections in order to reduce the risk of static electricity.
  • Page 9: Cooled Mechanical Seal

    Protection against motor overload, suitable for the motor’s nominal power must also be installed. If necessary, install a separate fan, bearing in mind the environment where it will operate (potentially explosive atmosphere). 4.6.1. Automatic circuit-breaker It must be remember that these automatic circuit-breakers have to work in a potentially explosive atmosphere.
  • Page 10 4.7.1. Single mechanical seal option If the single mechanical seal is working in dry conditions, its maximum operating temperature may be exceeded. This is why a simple mechanical seal must not operate under any circumstances in dry conditions. Regularly check that the single mechanical seal is functioning correctly. •...
  • Page 11: Starting Up

    5. Starting up Before starting up, those responsible must be duly informed about the pump and the safety instructions. This Annex, along with the instructions manual, will be available to staff at all times. In order to carry out any type of work in potentially explosive atmospheres, it is necessary to adopt special safety measures such as permits to work.
  • Page 12: Maintenance

    6. Maintenance 6.1. GENERAL INFORMATION The maintenance work of any equipment intended for use in potentially explosive atmospheres can only be carried out with the appropriate permit to work, as specified by ATEX 2014/34/UE. Maintenance jobs can only be done by qualified personnel. Use the proper clothing. Ensure that staff read the entire instructions manual and this Annex and, in particular, indicate those chapters that refer to the job to be done.
  • Page 13: Cleaning

    When ordering spare parts for a pump operating within a classified area, it must be expressly stated that the pump is an ATEX pump and quote the manufacture number. Otherwise, Inoxpa cannot ensure that the pump operates with parts that are suitable for the classified. 6.4. PAINTWORK If rust appears on the painted surface of the lantern, the affected area must be repainted in order to avoid the risk of any abnormalities.
  • Page 14: Disassembly / Assembly Of The Pump

    INOXPA disclaims any liability for accidents or damage caused by failure to observe the instructions of the manual and of this Annex. 6.7.1. Preparations As well as the instructions given in the manual, the possibility of the presence of an explosive atmosphere must also be considered.
  • Page 15: Technical Specifications

    7. Technical Specifications To see 4.1.1. point to the maximum temperature values. Materials Parts in contact with the product AISI 316L (1.4404) Other Steel parts AISI 304L (1.4306) Gaskets in contact with the product EPDM (standard) FPM (other materials available upon request) Surface finish Polished Ra ≤...
  • Page 16 NOTAS...
  • Page 17 INOXPA COLOMBIA SAS BOGOTÁ S.T.A. PORTUGUESA LDA Pbx 57-1-7427577 ALGERIZ inoxpa.colombia@inoxpa.com Tel. +351 256472722 comercial.pt@inoxpa.com In addition to our branches, INOXPA has a network of independent distributors in over 50 countries worldwide. For further information, visit our website www.inoxpa.com...