Mandatory to ensure safety at the workplace Mandatory use of safety goggles 1.4. GENERAL SAFETY INSTRUCTIONS Read the instruction manual carefully before installing and starting the table blender. Contact INOXPA in case of doubt. 1.4.1. During the installation Technical Specifications of Chapter 8 should always be observed.
Page 5
• Risk to the environment due to the type of substances released. 1.4.5. Warranty Any warranty will be void immediately and lawfully; additionally, INOXPA will be compensated for any civil liability claims submitted by third parties, in the following cases: •...
Page 6
The usage of other parts will relieve the manufacturer of any liability. Changing the service conditions can only be carried out with prior written authorisation from INOXPA Please do not hesitate to contact us in case of doubts or if further explanations are required regarding specific data (adjustments, assembly, disassembly, etc.).
3. General Information 3.1. DESCRIPTION This blender is comprised of a centrifugal pump that as an option feeds an in-line mixer. A device is installed at the pump’s intake that is used for introducing solids, which are suctioned from the hopper incorporated on the frame. This unit is approved for use with food products.
The field of application for each type of blender is limited. The blender is usually selected for certain working conditions present at the time it is ordered. INOXPA will not be liable for any damage that may occur if the information provided by the buyer is incomplete (specifications of the liquid, RPM, etc.).
4. Installation 4.1. RECEPTION OF THE BLENDER INOXPA will not be liable for any deterioration of the material due to transport or unpacking. Visually check that the packaging has not been damaged. The following documentation is included with the blender: •...
4.2. TRANSPORT AND STORAGE The blenders incorporate wheels so they can be moved but in case of being stored for shipping, refer to the diagram for lifting the unit Lift the blender as indicated below: ATTENTION! Make sure that the blender is secured to prevent overturn it.
4.5. DOUBLE MECHANICAL SEAL Models with double mechanical seal may require the installation of auxiliary cooling circuit for them. As shown in next figure, will be assembled the inlet connection on the bottom and the outlet on the top ensuring that the chamber is full of liquid.
Page 13
ATTENTION! See indicator label on the pump and/or the mixer. Start and stop the pump and/or mixer motor momentarily. Make sure, looking at the pump from behind, that the motor fan rotates in a clockwise direction. ALWAYS check the direction of rotation of the motor with liquid inside the blender. For models with a seal chamber, ALWAYS ensure that it is full of liquid prior to checking the direction of rotation.
5.1. START-UP Technical Specifications Carefully read Section 8. . INOXPA will not be liable for improper use of the equipment. NEVER touch the blender or the lines if hot liquids are being pumped. 5.1.1. Checks before starting the table blender •...
The attached table lists solutions to problems that may arise while operating the blender. It is assumed that the blender has been properly installed and that is has been selected correctly for the specific application. Contact INOXPA if technical assistance is required. Motor overload The pump flow or pressure is insufficient.
7. Maintenance 7.1. GENERAL CONSIDERATIONS This blender, just like any other machine, requires maintenance. The instructions contained in this manual cover the identification and replacement of spare parts. The instructions are aimed at maintenance personnel and those responsible for the supply of spare parts. Technical Specifications Carefully read Chapter 8.
Page 17
Check the concentration of the cleaning solutions; incorrect concentrations may lead to deterioration of the blender seals. To remove any traces of cleaning products, ALWAYS perform a final rinse with clean water at the end of the cleaning process. 7.3.2. SIP (Sterilization-in-Place) cleaning Sterilization with steam is applied to all equipment including the blender.
7.4. DISASSEMBLY / ASSEMBLY OF THE TABLE BLENDER 7.4.1. Hopper, venturi tube and discharge tube (only in mixer option) Disassembly Remove the clamp (91) from the bottom of the hopper. Remove the blind nuts (54) and the flat washers (53). Extract the hopper (101) by moving it upward, taking into account that the flat washer (18) and the clamp seal (91B) will be unattached.
Page 19
Assembly Install the discharge valve (96A) on the pump by means of seal (91E) and clamp (91D). Attach the discharge tube (98) to the elbow clamp from mixer’s entrance by means of seal (91C) and clamp (91A). Finally, fasten the discharge tube (98) to the discharge valve (96A) using seal (91E) and clamp (91D). Position the venturi tube (102) on the tube clamp (38A) but do not tighten down.
8.2. TIGHTENING TORQUES If not stated otherwise, the torques listed in the following table should be applied on the nuts and bolts of this blender. Size lbf·ft 8.3. WEIGHTS Size MM-1 MM-2 MM-3 MM-1M MM-2M MM-3M 1390 8.Technical Specifications 2021/11...
Page 28
Fax: 86 573 83 570 038 e-mail: spb@inoxpa.com INOXPA UCRANIA KIEV Tel: 38 050 720 8692 e-mail: kiev@inoxpa.com In addition to our branches, INOXPA has a network of independent distributors in over 50 countries worldwide. For further information, visit our website. www.inoxpa.com...