Download Print this page

Pro-Craft PSE1100 Manual page 26

High pressure spray station

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 20
5.
Continue this process until only cleaning solution
is ejected from the spray tip. Add
more cleaning solution if all of the paint has not been
removed.
Note: If the cleaning solution bucket becomes cloudy
with paint during cleaning, skip to
section: Cleaning of the inlet hose. Once the inlet filter
and hose are clean, re-assemble
them and repeat steps 3-6.
6.
Move the priming lever to the priming position.
Then switch the unit off and disconnect it from the
power supply.
Note: This cleaning process must be followed
immediately after use to prevent paint from drying inside
the pump and hose. Failure to follow this instruction may
permanently seize the paint sprayer.
For Water Based Cleaning
We recommend the use of 10-15 litres when performing
the cleaning procedure.
For Oil Based Cleaning
We recommend 1-2 litres of the appropriate solvent
based cleaner when performing the cleaning procedure.
Note: If you have not finished painting with your airless
sprayer and want to take a short break (30-60 minutes),
do not leave paint sitting inside the pump. Perform steps
3-5 above to prevent paint from drying inside the pump &
hose.
Once you're ready to begin work again simply follow the
spraying instructions in the user manual. Once properly
primed again, aim the spray gun into a waste bucket and
allow 30 seconds for any leftover cleaning solution to be
flushed out of the system. Then resume painting as
normal.
Note: Mineral Turpentine SHOULD NOT be mixed with
water at any stage during the cleaning process.
CLEANING THE INLET HOSE
1.
Unscrew the butterfly clamp on the inlet hose and
slide the hose clamp away from the filter.
2.
Pull the filter out and rinse under appropriate
cleaning solution.
Note: If filter cannot be cleaned it must be replaced.
CLEANING THE SPRAY GUN
WARNING! ENSURE THE UNIT IS OFF AND THE
PRESSURE RELEASE
PROCEDURE HAS BEEN PERFORMED.
1.
Remove the spray gun from the high pressure hose
by loosening the nut with a 19mm spanner.
2.
Remove the nozzle guard and spray tip by
loosening the retaining nut. Once the guard
assembly has been removed, pull the nozzle tip
out.
26
EN | ENGLISH

Advertisement

loading