CLEANING THE UNIT
Note: Before beginning cleaning procedure ensure the
pressure control dial is set to a
medium to high setting and the priming lever is in the
prime position.
1.
Place the inlet hose into a bucket of appropriate
cleaning solution. Place the return hose into an
empty bucket or container.
2.
Turn the unit on, ensuring the priming lever is set
to prime position. Check the return hose and wait
for a constant stream of clear cleaning solution to
pass out of it. Then set the priming lever to the
spray position.
3.
Aim the spray gun into an empty bucket or
container. Squeeze and hold the spray gun trigger
until most of the paint is removed from the high
pressure hose.
4.
Lock the spray gun trigger. Rotate the spray tip
180° to the cleaning side. Unlock the spray gun
trigger. Squeeze and hold the spray gun trigger to
spray the cleaning solution through the system.