45
6.9.3
Water system in the fridge room
9—Water tube (
white, flow into the water tank in fridge room)
14—Water tank
15—Electrically operated valve (DC12V)
16—Water tube (white, flow from water tank to the dispenser on fridge wall)
6.10 Ice maker& Water valve
6.10.1 Checking method
Step 1. Check the connecting wiring between water valve and mainboard is well or not.
Repair if it is broken.
Step 2. Check water line connection well.
Step 3. Touch and hold "Super Freeze" button and "Freezer" button at the same time for
3 seconds in 15 minutes after power-on, ice tray will be turned, if not, please replace the
ice maker part.
Step 4. Touch and hold "Super Freeze" button and "Super Cool" button at the same time
for 3 seconds in 15 minutes after power-on, the water and ice valve will be opened for
180S, if not, please replace the water valve.
Meanwhile, the "
flicker frequency. If it flashes once 0.5 second, it indicates that the flow-sensor is ok; if not
flicker, it indicates that the flow-sensor is abnormal. It is necessary to check the wiring or
replace the water valve.
In the
icon flicker process, hold and press"Super Freeze"button+"Super
Cool " button for 3 seconds or power off can end testing.
" icon starts flashing on display board, observe the
Hisense Refrigerator
icon