Siemens SIRIUS 3RA2711 Equipment Manual page 82

Industrial switchgear
Table of Contents

Advertisement

Connecting
10.1 Connection via terminals
Spring-loaded terminals
For the conductor cross-sections and stripping lengths, see the table.
Table 10-2
Connection type
 
82
Conductor cross-sections for spring-loaded terminals
AWG
To release the clamping springs, insert the screwdriver as far as it will go into the square opening
of the spring-loaded terminal.
Angle the screwdriver up and insert it fully in the actuation opening.
The screwdriver blade automatically keeps the spring-loaded terminal open.
Insert the cable as far as it will go into the oval opening and hold it in place.
Remove the screwdriver. The terminal closes and the conductor is now securely clamped.
Pull on the cable to ensure it is tight.
Conductor cross-section
2 x (0.25 ... 1.5) mm
2 x (0.25 ... 1.5) mm
2 x (0.25 ... 1.5) mm
Equipment Manual, 08/2022, A8E96801709001A/RS-AD/006
3RA2908‑1A
(3.0 x 0.5) mm
2
2
2
2 x (24 to 16)
SIRIUS 3RA2711 function modules for IO-Link