Setting The Rear Stop Label - YILMAZ KP 120 Manual

Table of Contents

Advertisement

Available languages

Available languages

7.3 Setting the Rear Stop Label

7.3.1 1mm movement of the profile back lean is reflected on the work as 0.8966 mm. The interval in each line of the
adjusting measurement label on back lean (PICTURE 3 NO.37) is divided as 0.8966 mm.
7.3.2 If the profile back lean is requested to be made not from the place impressed by the pressing blades (the part
shown in PICTURE 7 and PICTURE 8 as 9.5 mm) but from different part of the aluminum profile (according to
the feature of aluminum profile, due to reasons such as central leaning or failure of pressing blade to enter
among the profile etc.), serial and accurate adjustments can be made at the first adjustment stages by making
the following sample calculations.
7.3.3 Sample: If the difference between the profile lean surface in PICTURE 8 and the lowest part impressed by the
pressing blade is 15 mm, then 15 x 1.577 (fixed value) = 23.65 mm is found. Let's add this value to the profile
junction distance shown in figure 21. 23.65 + 53 = 76.65 value is found. Please fasten the back lean by
observing 76.65 value on the label. (PICTURE 10)
PICTURE 7
PICTURE 8
36