WARNING: THIS CONVERSION KIT SHALL BE INSTALLED
BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH
THE MANUFACTURER'S INSTRUCTIONS AND ALL APPLI-
CABLE CODES AND REQUIREMENTS OF THE AUTHORIZED
AGENCY HAVING JURISDICTION. IF THE INFORMATION IN
THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A
FIRE, EXPLOSION OR PRODUCTION OF CARBON MONOX-
IDE MAY RESULT CAUSING PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF LIFE. THE INSTALLATION IS
NOT PROPER AND COMPLETE UNTIL THE OPERATION OF
THE CONVERTED APPLIANCE IS CHECKED AS SPECIFIED IN
THE OWNER INSTRUCTIONS SUPPLIED WITH THE KIT.
In Canada
THE CONVERSION SHALL BE CARRIED OUT
IN ACCORDANCE WITH THE REQUIREMENTS
OF THE PROVINCIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE WITH
THE REQUIREMENTS OF THE CAN1-B149.1
AND .2 INSTALLATION CODE.
LA CONVERSION DEVRA ÊTRE EFFECTUÉE
CONFORMÉMENT AUX RECOMMANDATIONS
DES AUTORITÉS PROVINCIALES AYANT
JURIDICTION ET CONFORMÉMENT AUX
EXIGENCES DU CODE D'INSTALLATION CAN1-
B149.1 ET.2.
This Gas Conversion Kit contains all of the
necessary components needed to complete the
conversion of an appliance from the use of one
type of gas to the use of another, including
labeling that must be affixed to ensure safe
operation.
ALWAYS REFER TO THE APPLIANCE IN-
STALLATION AND HOMEOWNERS CARE
AND OPERATION DOCUMENTS BEFORE
C O M P L E T I N G A C O N V E R S I O N . A L L
WARNINGS, CAUTIONS AND DETAILED
INSTRUCTIONS CONTAINED THEREIN
ARE APPLICABLE TO THIS DOCUMENT.
750,149M REV. N/C
8/2002
P750083M
P/N 750149M Rev. A 05/2015
AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION SERA INSTALLÉ
PAR UNE AGENCE QUALIFIÉE DE SERVICE CONFORMÉMENT AUX
INSTRUCTIONS DU FABRICANT ET TOUTES EXIGENCES ET CODES
APPLICABLES DE L'AUTORISÉS AVOIR LA JURIDICTION. SI
L'INFORMATION DANS CETTE INSTRUCTION N'EST PAS SUIVIE
EXACTEMENT, UN FEU, EXPLOSION OU PRODUCTION DE PROTOXYDE
DE CARBONE PEUT RÉSULTER LE DOMMAGES CAUSER DE
PROPRIÉTÉ, PERTE OU BLESSURE PERSONNELLE DE VIE. L'AGENCE
QUALIFIÉE DE SERVICE EST ESPONSABLE DE L'INSTALLATION
PROPRE DE CET ÉQUIPMENT. L'INSTALLATION N'EST PAS PROPRE
ET COMPLÉTE JUSQU'À L'OPÉRATION DE L'APPAREIL CONVERTI EST
CHÉQUE SUIVANT LES CRITÈRES ÉTABLIS DANS LES INSTRUCTIONS
DE PROPRIÉTAIRE PROVISIONNÉES AVEC L'ÉQUIPEMENT.
To complete the conversion proceed as follows:
Note: After converting the valve and gas compo-
nents, refer to the appliance installation and
homeowners care and operation instructions to
adjust the air shutter opening for the gas type used.
Step 1. Turn off the gas supply to the
appliance. Remove the front frame and
glass door from the appliance. Access the
control compartment.
Step 2. Carefully remove the logs. Exercise
care as not to break the logs.
Step 3. Remove the grate.
Burner Clamp
Securing Screw
Burner Clamp
Front Burner
Securing Screw
Figure 1
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
HEARTH PRODUCTS
KITS AND ACCESSORIES
GAS CONVERSION KIT
GAS CONVERSION KIT (GCK-LS)
See Figure 1 for step 4 part removal details:
Step 4
a. Remove the front baffle by remov-
ing the two securing screws.
b. Remove the two screws securing
the end tabs of the front burner. Remove the
front burner.
c. Remove the two screws securing
each of the rear burner clamps. Remove the
rear burner.
Rear Burner
Securing Screw
Front Baffle
Front Burner
Burner Assembly
HEARTH PRODUCTS
KITS AND ACCESSORIES
(GCK-LS)
Front Baffle
1
1

Advertisement

loading

Summary of Contents for IHP GCK-LS

  • Page 1 8/2002 P750083M (GCK-LS) P/N 750149M Rev. A 05/2015 GAS CONVERSION KIT (GCK-LS) AVERTISSEMENT: CET ÉQUIPEMENT DE CONVERSION SERA INSTALLÉ WARNING: THIS CONVERSION KIT SHALL BE INSTALLED PAR UNE AGENCE QUALIFIÉE DE SERVICE CONFORMÉMENT AUX BY A QUALIFIED SERVICE AGENCY IN ACCORDANCE WITH...
  • Page 2 Step 5. c. Insert the conversion plug for the Step 6 fuel being used as shown in Figure 3 . Use the Convert the Honeywell RF Comfort a. Convert the pilot orifice as follows red plug for LP/propane gas usage or the Control Valve as follows: (see Figures 4, 5 and 6 on page 3): blue one for natural gas.
  • Page 3 Step 7. Unscrew the rear and front main burner orifices (Figure 7) from their respec- Pilot for the Honeywell RF Comfort Control Valve tive manifolds and replace them with the (Loosening of Hex Fitting For Orifice Strip Tab Positioning) ones provided in this kit. There are two main burner orifices provided in this gas conver- Hood Alignment Hood...
  • Page 4 1508 Elm Hill Pike, Suite 108 P/N 750,149M REV. N/C 8/2002 1110 West Taft Avenue • Orange, CA 92865 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Printed in U.S.A. © 2015 INNOVATIVE HEARTH PRODUCTS LLC Nashville, TN 37210 P750149M P/N 750149M Rev. A 05/2015 IHP.US.COM...