IHP MAGNIFLAMEOD24NE Owner's Operation And Installation Manual

Vented gas log appliance accessory, mfeb magniflame ember bed accessory burner kit cat. no. f0253 for use only with burner system models

Advertisement

Quick Links

P/N 126913-01 REV. A 04/2017
The MFEB accessory kit may only be used when installed
in a wood burning fi replace and may only be used with
the burner systems and log models listed in this manual.
DANGER
f i r e - p a r t s . c o m
WARNING: No not store gasoline or other fl amable vapors and liquids in the vicinity of
this or any other appliance. An LP-cylinder not connected for use shall not be stored in the
vicinity of this or any other appliance.
WARNING: Improper installation, adjustment, alteration, service or maintenance can
cause injury or property damage. Read the installation, operating and maintenance instruc-
tions thoroughly before installing or servicing this equipment.
WARNING: If the information in this manual is not followed exactly, a fi re or explosion
may result causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of
this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fi re department.
— Installation and service must be performed by a qualifi ed installer, service agency or the
gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
WHEN USED AS AN OUTDOOR APPLIANCE
CARBON MONOXIDE
WARNING
This appliance can pro-
duce carbon monoxide
which has no odor.
Using it in an enclosed
space can kill you.
Never use this appli-
ance in an enclosed
space such as a camp-
er, tent, car or home.
WHEN USED AS INDOOR VENTED APPLIANCE
For more information, visit IHP.us.com
VENTED GAS LOG APPLIANCE ACCESSORY
OWNER'S OPERATION AND INSTALLATION
MANUAL
MFEB MAGNIFLAME EMBER BED ACCESSORY
BURNER KIT (CAT. NO. F0253) FOR USE ONLY
WITH BURNER SYSTEM MODELS
MAGNIFLAMEOD24NE, MAGNIFLAMEOD24NM,
MAGNIFLAMEOD24PE, MAGNIFLAMEOD24PM,
MAGNIFLAMEOD30NE, MAGNIFLAMEOD30NM,
MAGNIFLAMEOD30PE, MAGNIFLAMEOD30PM,
MFBOD24MN, MFBOD24MP, MNF24ONE, MNF24ONM,
MNF24OPE, MNF24OPM, MNF30ONE, MNF30ONM,
MNF30OPE, MNF30OPM
WARNING: For Outdoor Use Only.
DANGER
IF YOU SMELL GAS:
1. Shut off gas to appliance.
2. Extinguish any open fl ame.
3. If odor continues, keep away from the
appliance and immediately call your gas
supplier or fi re department.

Advertisement

Table of Contents
loading

Summary of Contents for IHP MAGNIFLAMEOD24NE

  • Page 1 • If you cannot reach your gas supplier, call the fi re department. — Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. For more information, visit IHP.us.com...
  • Page 2: Table Of Contents

    Carefully supervise young children when they are in the room with appliance. When using the hand-held remote accessory, keep selector switch in the OFF position to prevent children from turning on burners with remote. IHP.us.com 126913-01A...
  • Page 3 9. Do not use this appliance as a wood burning appliance. Use only the logs provided with the appliance. Do not burn solid fuels in this appliance. 10.Do not run appliance • where fl ammable liquids or vapors are used or stored • under dusty conditions IHP.us.com 126913-01A...
  • Page 4: Local Codes

    fi replace or Floor 5", Front: 36" a UL 127 listed wood burning fi replace. The fi replace's vent damper must be locked in the open position. This accessory may be used either indoors or outdoors. IHP.us.com 126913-01A...
  • Page 5 (stamped ''52'') must be removed, (see Figure 4, page 6). must be cut or removed. IHP.us.com 126913-01A...
  • Page 6 fl ex line as shown. Tighten the nuts using a wrench. Burner Clamp Ferrule Stainless Steel Flex Line Tee Connector Burner Tube Screw Figure 6 - Attaching Burner Clamp to burner Pan Figure 9 - Attaching stainless steel Flex Line IHP.us.com 126913-01A...
  • Page 7 If pipe is too small, undue loss of volume will occur. Installation must include an equipment shutoff valve, union and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from appli- ance (see Figure 11). IHP.us.com 126913-01A...
  • Page 8 2. Pressurize supply piping system by either opening pro- Control Valve pane/LP supply tank valve for propane/LP gas or opening Location main gas valve located on or near gas meter for natural gas or using compressed air. Figure 14 - Checking Gas Joints (Natural Gas Only) IHP.us.com 126913-01A...
  • Page 9: Operation

    Apply the material for your application on the burner pan by Normally, all parts should be ordered through your IHP distributor spreading it evenly across the burner pan so that it is level or dealer.
  • Page 10: Troubleshooting

    IMPORTANT: Operating appliance where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time. IHP.us.com 126913-01A...
  • Page 11: Parts

    PARTS AVAILABLE, NOT SHOWN - ALL MODELS J7274 Vermiculite, Pln. Bag #1.00 J7275 Pan Material - 0.4# Pln. Bag Ember J7287 Clamp Damper J7096 Lava Rock Bag Assembly 4.5 Lbs. J4714 Flex Tube J4733 Compression Nut and Ferrule IHP.us.com 126913-01A...
  • Page 12 - p a r t s . c o m IHP reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products. Consult your local distributor for fi replace code information.

Table of Contents